Search Results

Filter
  • 1-10 of  1,194 results for ""Nucleic Acid Amplification Techniques""
Item request has been placed! ×
Item request cannot be made. ×
loading  Processing Request
Academic Journal

Detection of severe acute respiratory syndrome coronavirus 2 in bioaerosols using digital droplet polymerase chain reaction and loop-mediated isothermal amplification.

  • Authors : Zhang X; Hunan Key Laboratory of Biomedical Nanomaterials and Devices, Hunan University of Technology, Zhuzhou, Hunan, 412007, PR China. .; Procurement and Distribution Centre, Jiangsu Province Hospital of TCM, Affiliated Hospital of Nanjing University of Chinese Medicine, Nanjing 210029, PR China.

Subjects: SARS-CoV-2*/SARS-CoV-2*/SARS-CoV-2*/genetics ; SARS-CoV-2*/SARS-CoV-2*/SARS-CoV-2*/isolation & purification ; Nucleic Acid Amplification Techniques*/Nucleic Acid Amplification Techniques*/Nucleic Acid Amplification Techniques*/methods LAMP assay

  • Source: Analytical methods : advancing methods and applications [Anal Methods] 2024 Dec 12; Vol. 16 (48), pp. 8449-8456. Date of Electronic Publication: 2024 Dec 12.Publisher: RSC Pub Country of Publication: England NLM ID: 101519733 Publication Model: Electronic Cited Medium: Internet ISSN: 1759-9679

Record details

×
Academic Journal

PI primers increase the efficacy of LAMP and RT-LAMP for SARS-CoV-2 and MS2 phage detection.

  • Authors : Oscorbin IP; Laboratory of Pharmacogenomics, Institute of Chemical Biology and Fundamental Medicine, Siberian Branch of the Russian Academy of Sciences, 8 Lavrentiev Avenue, 630090 Novosibirsk, Russia. Electronic address: .; Novikova LM

Subjects: COVID-19*/COVID-19*/COVID-19*/diagnosis ; COVID-19*/COVID-19*/COVID-19*/virology ; DNA Primers*/DNA Primers*/DNA Primers*/genetics LAMP assay

  • Source: Diagnostic microbiology and infectious disease [Diagn Microbiol Infect Dis] 2024 Nov; Vol. 110 (3), pp. 116449. Date of Electronic Publication: 2024 Jul 17.Publisher: Elsevier Biomedical Country of Publication: United States NLM ID: 8305899 Publication Model: Print-Electronic Cited Medium: Internet ISSN:

Record details

×
Academic Journal

Point-of-care testing for COVID-19: a simple two-step molecular diagnostic development and validation during the SARS-CoV-2 pandemic.

  • Authors : Yoshikawa AAG; Universidade Federal de Santa Catarina, Departamento de Biologia Celular, Embriologia e Genética, Florianópolis, SC, Brasil.; Cardoso SF

Subjects: COVID-19*/COVID-19*/COVID-19*/diagnosis ; Point-of-Care Testing* ; SARS-CoV-2*/SARS-CoV-2*/SARS-CoV-2*/genetics LAMP assay

  • Source: Memorias do Instituto Oswaldo Cruz [Mem Inst Oswaldo Cruz] 2024 Oct 04; Vol. 119, pp. e230236. Date of Electronic Publication: 2024 Oct 04 (Print Publication: 2024).Publisher: Instituto Oswaldo Cruz Country of Publication: Brazil NLM ID: 7502619 Publication Model: eCollection Cited Medium: Internet ISSN:

Record details

×
Academic Journal

Enhancing efficiency in detection of COVID-19 through AI-driven colorimetric isothermal detection with multiplex primers.

  • Authors : Jaroenram W; National Center for Genetic Engineering and Biotechnology (BIOTEC), National Science and Technology Development Agency (NSTDA), 111 Thailand Science Park, Phahonyothin Rd., Klong Neung, Klong Luang, Pathum Thani 12120, Thailand.; Teerapittayanon S

Subjects: Colorimetry*/Colorimetry*/Colorimetry*/methods ; COVID-19*/COVID-19*/COVID-19*/diagnosis ; COVID-19*/COVID-19*/COVID-19*/virology LAMP assay

  • Source: Diagnostic microbiology and infectious disease [Diagn Microbiol Infect Dis] 2024 Oct; Vol. 110 (2), pp. 116446. Date of Electronic Publication: 2024 Jul 25.Publisher: Elsevier Biomedical Country of Publication: United States NLM ID: 8305899 Publication Model: Print-Electronic Cited Medium: Internet ISSN:

Record details

×
Academic Journal

A compact, palm-sized isothermal fluorescent diagnostic intelligent IoT device for personal health monitoring and beyond via one-tube/one-step LAMP-CRISPR assay.

  • Authors : Dai F; Academy of Medical Engineering and Translational Medicine, Medical College, Tianjin University, Tianjin, 300072, China; Hangzhou Institute of Medicine, Chinese Academy of Sciences, Hangzhou, Zhejiang, 310022, China.

Subjects: Biosensing Techniques*/Biosensing Techniques*/Biosensing Techniques*/instrumentation ; Biosensing Techniques*/Biosensing Techniques*/Biosensing Techniques*/methods ; Nucleic Acid Amplification Techniques*/Nucleic Acid Amplification Techniques*/Nucleic Acid Amplification Techniques*/instrumentation LAMP assay

  • Source: Biosensors & bioelectronics [Biosens Bioelectron] 2025 Feb 15; Vol. 270, pp. 116945. Date of Electronic Publication: 2024 Nov 14.Publisher: Elsevier Advanced Technology Country of Publication: England NLM ID: 9001289 Publication Model: Print-Electronic Cited Medium: Internet

Record details

×
Academic Journal

Facilitating self-testing with a fast, accurate, and simplified shelf-stable colorimetric LAMP system for Mpox and SARS-CoV-2 detection.

  • Authors : Odiwuor N; WHP Innovation Lab, Wuhan Institute of Virology, Chinese Academy of Sciences, Wuhan, Hubei 430207, China; University of Chinese Academy of Sciences, Beijing, 100049, China

Subjects: Nucleic Acid Amplification Techniques*/Nucleic Acid Amplification Techniques*/Nucleic Acid Amplification Techniques*/methods ; Colorimetry*/Colorimetry*/Colorimetry*/methods ; SARS-CoV-2*/SARS-CoV-2*/SARS-CoV-2*/isolation & purification LAMP assay

  • Source: Talanta [Talanta] 2025 Feb 01; Vol. 283, pp. 127119. Date of Electronic Publication: 2024 Nov 04.Publisher: Elsevier Country of Publication: Netherlands NLM ID: 2984816R Publication Model: Print-Electronic Cited Medium: Internet ISSN:

Record details

×
Academic Journal

Evaluation of a field deployable, high-throughput RT-LAMP device as an early warning system for COVID-19 through SARS-CoV-2 measurements in wastewater.

  • Authors : Boza JM; Meinig School of Biomedical Engineering, Cornell University, Ithaca, NY 14850, USA.; Amirali A

Subjects: Wastewater*/Wastewater*/Wastewater*/virology ; COVID-19*/COVID-19*/COVID-19*/diagnosis ; SARS-CoV-2* LAMP assay

  • Source: The Science of the total environment [Sci Total Environ] 2024 Sep 20; Vol. 944, pp. 173744. Date of Electronic Publication: 2024 Jun 04.Publisher: Elsevier Country of Publication: Netherlands NLM ID: 0330500 Publication Model: Print-Electronic Cited Medium: Internet ISSN:

Record details

×
Academic Journal

A portable, easy-to-use paper-based biosensor for rapid in-field detection of fecal contamination on fresh produce farms.

  • Authors : Wang J; Department of Agricultural and Biological Engineering, Purdue University, West Lafayette, IN, 47907, USA; Birck Nanotechnology Center, Purdue University, West Lafayette, IN, 47907, USA.

Subjects: Biosensing Techniques*/Biosensing Techniques*/Biosensing Techniques*/instrumentation ; Biosensing Techniques*/Biosensing Techniques*/Biosensing Techniques*/methods ; Feces*/Feces*/Feces*/microbiology LAMP assay

  • Source: Biosensors & bioelectronics [Biosens Bioelectron] 2024 Sep 01; Vol. 259, pp. 116374. Date of Electronic Publication: 2024 May 10.Publisher: Elsevier Advanced Technology Country of Publication: England NLM ID: 9001289 Publication Model: Print-Electronic Cited Medium: Internet

Record details

×
Academic Journal

Paper-based loop-mediated isothermal amplification and CRISPR integrated platform for on-site nucleic acid testing of pathogens.

  • Authors : Sen A; DNAiTECH Ltd, Marlborough Research Center, 2650 State Highway 1, Grovetown, Blenheim, Marlborough, 7202, New Zealand.; Masetty M

Subjects: Nucleic Acid Amplification Techniques*/Nucleic Acid Amplification Techniques*/Nucleic Acid Amplification Techniques*/methods ; Nucleic Acid Amplification Techniques*/Nucleic Acid Amplification Techniques*/Nucleic Acid Amplification Techniques*/instrumentation ; Biosensing Techniques*/Biosensing Techniques*/Biosensing Techniques*/methods LAMP assay

  • Source: Biosensors & bioelectronics [Biosens Bioelectron] 2024 Aug 01; Vol. 257, pp. 116292. Date of Electronic Publication: 2024 Apr 17.Publisher: Elsevier Advanced Technology Country of Publication: England NLM ID: 9001289 Publication Model: Print-Electronic Cited Medium: Internet

Record details

×
Academic Journal

An Ultra-Compact and Low-Cost LAMP-Based Virus Detection Device.

  • Authors : Guo D; Shenzhen Research Institute, City University of Hong Kong, Shenzhen 518000, China.; Department of Biomedical Engineering, City University of Hong Kong, Hong Kong 999077, China.

Subjects: Nucleic Acid Amplification Techniques*/Nucleic Acid Amplification Techniques*/Nucleic Acid Amplification Techniques*/instrumentation ; Nucleic Acid Amplification Techniques*/Nucleic Acid Amplification Techniques*/Nucleic Acid Amplification Techniques*/methods ; SARS-CoV-2*/SARS-CoV-2*/SARS-CoV-2*/isolation & purification LAMP assay

  • Source: Sensors (Basel, Switzerland) [Sensors (Basel)] 2024 Jul 29; Vol. 24 (15). Date of Electronic Publication: 2024 Jul 29.Publisher: MDPI Country of Publication: Switzerland NLM ID: 101204366 Publication Model: Electronic Cited Medium: Internet ISSN: 1424-8220

Record details

×
  • 1-10 of  1,194 results for ""Nucleic Acid Amplification Techniques""