Item request has been placed!
×
Item request cannot be made.
×
Processing Request
Donor safety in triple plateletpheresis: results from the German and Austrian Plateletpheresis Study Group multicenter trial.
Item request has been placed!
×
Item request cannot be made.
×
Processing Request
- Additional Information
- Subject Terms:
- Abstract:
BACKGROUND: The objective was to investigate potential risks for apheresis donors associated with a triple-plateletpheresis (TP) program. STUDY DESIGN AND METHODS: Eleven hemapheresis centers randomly assigned 411 repeat donors (ratio, 1:1.2) to either double plateletpheresis (DP; 185 donors) or TP (226 donors) with a platelet (PLT) target content of at least 5.0 × 1011 PLTs/DP and at least 7.5 × 1011 PLTs/TP. The primary endpoint was procedure-related postapheresis PLT count of at least 150 × 109/L (probability, ≥98%). Secondary endpoints were apheresis characteristics and donor adverse reactions. RESULTS: In 6 of 1133 DPs (0.5%) in 4 of 185 donors (2.2%) and in 20 of 1020 TPs (2.0%) in 14 of 226 donors (6.2%), postapheresis PLT counts were below 150 × 109/L. There were marginal but significant differences in collection efficiency (DP, 69.2 ± 9.1%; TP, 70.9 ± 9.0%; p ≤ 0.0001) and collection rate (DP, 10.4 × 109 ± 2.3 × 109 PLTs/min; TP, 10.8 × 109 ± 2.3 × 109 PLTs/min; p ≤ 0.005). The PLT yields were 5.9 × 1011 ± 0.8 × 1011 PLTs for DP and 8.3 × 1011 ± 0.9 × 1011 PLT for TP (p ≤ 0.0001) at processing times of 59 ± 13 minutes (DP) versus 80 ± 16 minutes (TP; p ≤ 0.0001). Significant PLT recruitment (1.10 ± 0.14 vs. 1.20 ± 0.23; p < 0.0001) was seen for both DP and TP. DP and TP did not differ with regard to venous access problems (VAPs) without discontinuation (3.8% for both), but DP induced fewer VAPs with discontinuation (1.1% vs. 3.0%; p < 0.01). Mild citrate toxicity (1.7% vs. 3.9%; p < 0.01) and circulatory reactions (0.4% vs. 2.2%; p < 0.01) were more often noticed in TP, but caused no increase in discontinuations. CONCLUSIONS: TP results in an increase in mild donor reactions but does not significantly impair donor safety or product quality. [ABSTRACT FROM AUTHOR]
- Abstract:
Copyright of Transfusion is the property of Wiley-Blackwell and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
No Comments.