Comparison of liquid and dried blood for neonatal hemoglobinopathy screening: laboratory and programmatic issues.

Item request has been placed! ×
Item request cannot be made. ×
loading   Processing Request
  • Author(s): Papadea C;Papadea C; Eckman JR; Kuehnert RS; Platt AF
  • Source:
    Pediatrics [Pediatrics] 1994 Mar; Vol. 93 (3), pp. 427-32.
  • Publication Type:
    Comparative Study; Journal Article; Research Support, Non-U.S. Gov't; Research Support, U.S. Gov't, P.H.S.
  • Language:
    English
  • Additional Information
    • Source:
      Publisher: American Academy of Pediatrics Country of Publication: United States NLM ID: 0376422 Publication Model: Print Cited Medium: Print ISSN: 0031-4005 (Print) Linking ISSN: 00314005 NLM ISO Abbreviation: Pediatrics Subsets: MEDLINE
    • Publication Information:
      Publication: Elk Grove Village Il : American Academy of Pediatrics
      Original Publication: Springfield, Ill., Thomas.
    • Subject Terms:
    • Abstract:
      Objectives: To compare laboratory and programmatic issues in neonatal hemoglobin screening in two systems using either liquid cord blood or heel puncture blood dried on filter paper (DB) to determine the accuracy of hemoglobin phenotype; the collection rate of cord blood versus DB; and the types of and reasons for errors.
      Methods: Cord blood samples for 6904 newborns were analyzed by electrophoresis in a large hospital laboratory. DB samples on the same cohort were analyzed by isoelectric focusing in a state public health laboratory.
      Results: Interlaboratory concordance was 99.4% for 6904 matched specimen pairs, which included 27 disease and 596 carrier phenotypes. In 42 pairs, discordances for potential disease phenotypes occurred with cord blood samples. Errors involving carrier phenotypes occurred in 15 cord blood samples and 14 DB samples. Inconclusive results requiring repeat testing occurred more often in the cord blood testing system (92) than in the DB system (23). Clerical transcriptions and limitations of the techniques accounted for most laboratory errors. Noncompliance in sample collection occurred more frequently with cord blood (181) than DB (86).
      Conclusions: Both systems are subject to errors, but are equally reliable for neonatal hemoglobinopathy screening.
    • Grant Information:
      MCJ-131005-01 United States PHS HHS
    • Accession Number:
      0 (Hemoglobins)
      0 (Hemoglobins, Abnormal)
      9034-51-9 (Hemoglobin A)
      9056-09-1 (hemoglobin Bart's)
    • Publication Date:
      Date Created: 19940301 Date Completed: 19940331 Latest Revision: 20100324
    • Publication Date:
      20240829
    • Accession Number:
      8115202