Hybridized deep learning goniometry for improved precision in Ehlers-Danlos Syndrome (EDS) evaluation.
Item request has been placed!
×
Item request cannot be made.
×
Processing Request
- Additional Information
- Source:
Publisher: BioMed Central Country of Publication: England NLM ID: 101088682 Publication Model: Electronic Cited Medium: Internet ISSN: 1472-6947 (Electronic) Linking ISSN: 14726947 NLM ISO Abbreviation: BMC Med Inform Decis Mak Subsets: MEDLINE
- Publication Information:
Original Publication: London : BioMed Central, [2001-
- Subject Terms:
- Abstract:
Background: Generalized Joint Hyper-mobility (GJH) can aid in the diagnosis of Ehlers-Danlos Syndrome (EDS), a complex genetic connective tissue disorder with clinical features that can mimic other disease processes. Our study focuses on developing a unique image-based goniometry system, the HybridPoseNet, which utilizes a hybrid deep learning model.
Objective: The proposed model is designed to provide the most accurate joint angle measurements in EDS appraisals. Using a hybrid of CNNs and HyperLSTMs in the pose estimation module of HybridPoseNet offers superior generalization and time consistency properties, setting it apart from existing complex libraries.
Methodology: HybridPoseNet integrates the spatial pattern recognition prowess of MobileNet-V2 with the sequential data processing capability of HyperLSTM units. The system captures the dynamic nature of joint motion by creating a model that learns from individual frames and the sequence of movements. The CNN module of HybridPoseNet was trained on a large and diverse data set before the fine-tuning of video data involving 50 individuals visiting the EDS clinic, focusing on joints that can hyperextend. HyperLSTMs have been incorporated in video frames to avoid any time breakage in joint angle estimation in consecutive frames. The model performance was evaluated using Spearman's coefficient correlation versus manual goniometry measurements, as well as by the human labeling of joint position, the second validation step.
Outcome: Preliminary findings demonstrate HybridPoseNet achieving a remarkable correlation with manual Goniometric measurements: thumb (rho = 0.847), elbows (rho = 0.822), knees (rho = 0.839), and fifth fingers (rho = 0.896), indicating that the newest model is considerably better. The model manifested a consistent performance in all joint assessments, hence not requiring selecting a variety of pose-measuring libraries for every joint. The presentation of HybridPoseNet contributes to achieving a combined and normalized approach to reviewing the mobility of joints, which has an overall enhancement of approximately 20% in accuracy compared to the regular pose estimation libraries. This innovation is very valuable to the field of medical diagnostics of connective tissue diseases and a vast improvement to its understanding.
(© 2024. The Author(s).)
- References:
BMJ Open. 2022 Dec 16;12(12):e068098. (PMID: 36526308)
Vasc Med. 2022 Jun;27(3):283-289. (PMID: 35000503)
Sensors (Basel). 2021 Apr 18;21(8):. (PMID: 33919583)
Int J Mol Sci. 2021 Sep 20;22(18):. (PMID: 34576312)
IEEE J Transl Eng Health Med. 2023 Nov 06;12:140-150. (PMID: 38088992)
Front Med (Lausanne). 2022 Sep 27;9:996458. (PMID: 36237549)
BMC Med Inform Decis Mak. 2024 May 16;24(1):127. (PMID: 38755570)
J Transl Autoimmun. 2020 Dec 20;4:100077. (PMID: 33437956)
Front Psychiatry. 2022 Jan 12;12:803614. (PMID: 35095619)
Mol Genet Genomic Med. 2022 Mar;10(3):e1885. (PMID: 35119775)
IEEE Trans Image Process. 2024;33:191-204. (PMID: 38060367)
- Contributed Indexing:
Keywords: Correlation; Diagnostics; Elbow; Fifth finger; Joints; Knees; LSTM; Manual; Measurement; Pose estimation; Spatial; Temporal; Thumb
- Publication Date:
Date Created: 20240718 Date Completed: 20240719 Latest Revision: 20240725
- Publication Date:
20240726
- Accession Number:
PMC11264507
- Accession Number:
10.1186/s12911-024-02601-4
- Accession Number:
39026270