Epidural pressure measurement using a fiber-optic sensor (proof-of-principle in vivo animal trial).

Item request has been placed! ×
Item request cannot be made. ×
loading   Processing Request
  • Additional Information
    • Source:
      Publisher: John Wiley & Sons, Inc Country of Publication: United States NLM ID: 101726292 Publication Model: Print-Electronic Cited Medium: Internet ISSN: 2576-2095 (Electronic) Linking ISSN: 25762095 NLM ISO Abbreviation: Animal Model Exp Med Subsets: MEDLINE
    • Publication Information:
      Original Publication: [Hoboken, New Jersey] : John Wiley & Sons, Inc., [2018]-
    • Subject Terms:
    • Abstract:
      Background: An increase in epidural pressure around the stenosis has been observed in patients with lumbar spinal stenosis (LSS) with positive signs of sedimentation or redundant nerve roots. Further analysis of the pressure conditions in the stenotic area would be of great interest. We hypothesized that it would be possible to determine the physiological parameters of the epidural pulse wave and its course in pathological stenosis as a basis for objective identification of LSS based on pressure using a new measuring method with continuous spatial and temporal resolution.
      Methods: We performed a single-case proof-of-principle in vivo animal trial and used a newly developed hybrid pressure-measurement probe with a fiber-tip Fabry-Pérot interferometer and several fiber Bragg gratings (FBG).
      Results: With reproducible precision, we determined the mean epidural pressure to be 7.5 mmHg and the peak-to-peak value to be 4-5 mmHg. When analyzing the pressure measured by an FBG array, both the heart and respiratory rates can be precisely determined. This study was the first to measure the pulse wave velocity of the cerebrospinal fluid pressure wave as 0.97 m/s using the newly developed pressure probe. A simulated LSS was detected in real time and located exactly.
      Conclusions: The developed fiber-optic pressure sensor probe enables a new objective measurement of epidural pressure. We confirmed our hypothesis that physiological parameters of the epidural pulse wave can be determined and that it is possible to identify an LSS.
      (© 2024 The Author(s). Animal Models and Experimental Medicine published by John Wiley & Sons Australia, Ltd on behalf of The Chinese Association for Laboratory Animal Sciences.)
    • References:
      Eur Spine J. 2014 May;23(5):985-90. (PMID: 24166020)
      Spine (Phila Pa 1976). 1995 Dec 15;20(24):2746-9. (PMID: 8747254)
      Hum Brain Mapp. 2021 Jun 1;42(8):2606-2622. (PMID: 33638224)
      Am J Physiol Regul Integr Comp Physiol. 2019 Sep 1;317(3):R470-R484. (PMID: 31242020)
      Orthop Clin North Am. 2003 Apr;34(2):281-95. (PMID: 12914268)
      Spine (Phila Pa 1976). 2015 Oct 1;40(19):1471-8. (PMID: 26208227)
      Front Bioeng Biotechnol. 2022 May 03;10:873530. (PMID: 35592552)
      Croat Med J. 2021 Aug 31;62(4):399-410. (PMID: 34472743)
      Spine (Phila Pa 1976). 2013 Mar 1;38(5):E263-9. (PMID: 23222648)
      Acta Neurol Belg. 2023 Oct;123(5):1781-1787. (PMID: 35934759)
      J Bone Joint Surg Br. 2012 Jan;94(1):98-101. (PMID: 22219255)
      BMJ Open. 2020 Sep 21;10(9):e037332. (PMID: 32958488)
      Eur Spine J. 2017 Jan;26(1):40-48. (PMID: 27858239)
      Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi. 2019 Jul 15;33(7):795-800. (PMID: 31297994)
      J Biomed Opt. 2016 Nov 1;21(11):117002. (PMID: 27819394)
      Neuroradiology. 2022 Nov;64(11):2191-2201. (PMID: 36083504)
      Spine (Phila Pa 1976). 1995 Mar 15;20(6):650-3. (PMID: 7604339)
      IEEE Trans Biomed Eng. 2009 Jun;56(6):1765-8. (PMID: 19174343)
      PLoS One. 2017 Nov 17;12(11):e0188364. (PMID: 29149204)
      Life (Basel). 2022 Mar 20;12(3):. (PMID: 35330208)
      Sensors (Basel). 2015 Jul 15;15(7):17115-48. (PMID: 26184228)
      J Bone Joint Surg Am. 2002 Nov;84(11):1954-9. (PMID: 12429755)
      Asian Spine J. 2021 Apr;15(2):207-215. (PMID: 32872759)
      Sensors (Basel). 2021 Aug 06;21(16):. (PMID: 34450771)
      Ann Biomed Eng. 2011 Jan;39(1):484-96. (PMID: 20737291)
      Pharmaceutics. 2022 Aug 24;14(9):. (PMID: 36145511)
      Sci Rep. 2022 Feb 16;12(1):2568. (PMID: 35173200)
      Eur Spine J. 2017 Oct;26(10):2573-2580. (PMID: 28161752)
      Front Neurol. 2022 Aug 09;13:951018. (PMID: 36016547)
      Eur Cell Mater. 2021 Mar 21;41:388-400. (PMID: 33745125)
      BMJ. 2016 Jan 04;352:h6234. (PMID: 26727925)
      Animal Model Exp Med. 2024 Oct;7(5):769-776. (PMID: 38981680)
      J Biophotonics. 2011 Apr;4(4):244-51. (PMID: 20575106)
    • Contributed Indexing:
      Keywords: animal; cerebrospinal fluid pressure; pulse wave velocity; spinal stenosis
    • Publication Date:
      Date Created: 20240709 Date Completed: 20241101 Latest Revision: 20241103
    • Publication Date:
      20241103
    • Accession Number:
      PMC11528391
    • Accession Number:
      10.1002/ame2.12469
    • Accession Number:
      38981680