Collagen degradation assessment with an in vitro rotator cuff tendinopathy model using multiparametric ultrashort-TE magnetization transfer (UTE-MT) imaging.

Item request has been placed! ×
Item request cannot be made. ×
loading   Processing Request
  • Additional Information
    • Source:
      Publisher: Wiley Country of Publication: United States NLM ID: 8505245 Publication Model: Print-Electronic Cited Medium: Internet ISSN: 1522-2594 (Electronic) Linking ISSN: 07403194 NLM ISO Abbreviation: Magn Reson Med Subsets: MEDLINE
    • Publication Information:
      Publication: 1999- : New York, NY : Wiley
      Original Publication: San Diego : Academic Press,
    • Subject Terms:
    • Abstract:
      Purpose: This study aims to assess ultrashort-TE magnetization transfer (UTE-MT) imaging of collagen degradation using an in vitro model of rotator cuff tendinopathy.
      Methods: Thirty-six supraspinatus tendon specimens were divided into three groups and treated with 600 U collagenase (Group 1), 150 U collagenase (Group 2), and phosphate buffer saline (Group 3). UTE-MT imaging was performed to assess changes in macromolecular fraction (MMF), macromolecule transverse relaxation time (T 2m ), water longitudinal relaxation rate constant (R 1m ), the magnetization exchange rate from the macromolecular to water pool (Rm 0 w ) and from water to the macromolecular pool (Rm 0 m ), and magnetization transfer ratio (MTR) at baseline and following digestion and their differences between groups. Biochemical and histological studies were conducted to determine the extent of collagen degradation. Correlation analyses were performed with MMF, T 2m , R 1m , Rm 0 w , Rm 0 m , and MTR, respectively. Univariate and multivariate linear regression analyses were performed to evaluate combinations of UTE-MT parameters to predict collagen degradation.
      Results: MMF, T 2m , R 1m , Rm 0 m , and MTR decreased after digestion. MMF (r = -0.842, p < 0.001), MTR (r = -0.78, p < 0.001), and Rm 0 m (r = -0.662, p < 0.001) were strongly negatively correlated with collagen degradation. The linear regression model of differences in MMF and Rm 0 m before and after digestion explained 68.9% of collagen degradation variation in the tendon. The model of postdigestion in MMF and T 2m and the model of MTR explained 54.2% and 52.3% of collagen degradation variation, respectively.
      Conclusion: This study highlighted the potential of UTE-MT parameters for evaluation of supraspinatus tendinopathy.
      (© 2024 International Society for Magnetic Resonance in Medicine.)
    • References:
      Allander E. Prevalence, incidence, and remission rates of some common rheumatic diseases or syndromes. Scand J Rheumatol. 1974;3:145‐153.
      Chard MD, Hazleman BL. Shoulder disorders in the elderly (a hospital study). Ann Rheum Dis. 1987;46:684‐687.
      Ashir A, Ma Y, Jerban S, et al. Rotator cuff tendon assessment in symptomatic and control groups using quantitative MRI. J Magn Reson Imaging. 2020;52:864‐872.
      Samiric T, Parkinson J, Ilic MZ, Cook J, Feller JA, Handley CJ. Changes in the composition of the extracellular matrix in patellar tendinopathy. Matrix Biol. 2009;28:230‐236.
      Riley GP, Harrall RL, Constant CR, Chard MD, Cawston TE, Hazleman BL. Tendon degeneration and chronic shoulder pain: changes in the collagen composition of the human rotator cuff tendons in rotator cuff tendinitis. Ann Rheum Dis. 1994;53:359‐366.
      Henkelman RM, Huang X, Xiang QS, Stanisz GJ, Swanson SD, Bronskill MJ. Quantitative interpretation of magnetization transfer. Magn Reson Med. 1993;29:759‐766.
      Sinclair CD, Samson RS, Thomas DL, et al. Quantitative magnetization transfer in in vivo healthy human skeletal muscle at 3 T. Magn Reson Med. 2010;64:1739‐1748.
      Ma YJ, Chang EY, Carl M, Du J. Quantitative magnetization transfer ultrashort echo time imaging using a time‐efficient 3D multispoke cones sequence. Magn Reson Med. 2018;79:692‐700.
      Ramani A, Dalton C, Miller DH, Tofts PS, Barker GJ. Precise estimate of fundamental in‐vivo MT parameters in human brain in clinically feasible times. Magn Reson Imaging. 2002;20:721‐731.
      Horsfield MA, Barker GJ, Barkhof F, Miller DH, Thompson AJ, Filippi M. Guidelines for using quantitative magnetization transfer magnetic resonance imaging for monitoring treatment of multiple sclerosis. J Magn Reson Imaging. 2003;17:389‐397.
      Boss A, Martirosian P, Küper K, Fierlbeck G, Claussen CD, Schick F. Whole‐body magnetization transfer contrast imaging. J Magn Reson Imaging. 2006;24:1183‐1187.
      Schmierer K, Wheeler‐Kingshott CA, Tozer DJ, et al. Quantitative magnetic resonance of postmortem multiple sclerosis brain before and after fixation. Magn Reson Med. 2008;59:268‐277.
      Baker JF, Conaghan PG, Emery P, Baker DG, Ostergaard M. Relationship of patient‐reported outcomes with MRI measures in rheumatoid arthritis. Ann Rheum Dis. 2017;76:486‐490.
      Benjamin M, Bydder GM. Magnetic resonance imaging of entheses using ultrashort TE (UTE) pulse sequences. J Magn Reson Imaging. 2007;25:381‐389.
      Du J, Bydder M, Takahashi AM, Carl M, Chung CB, Bydder GM. Short T2 contrast with three‐dimensional ultrashort echo time imaging. Magn Reson Imaging. 2011;29:470‐482.
      Chen B, Cheng X, Dorthe EW, et al. Evaluation of normal cadaveric Achilles tendon and enthesis with ultrashort echo time (UTE) magnetic resonance imaging and indentation testing. NMR Biomed. 2019;32:e4034.
      Chen B, Zhao Y, Cheng X, et al. Three‐dimensional ultrashort echo time cones (3D UTE‐cones) magnetic resonance imaging of entheses and tendons. Magn Reson Imaging. 2018;49:4‐9.
      Moazamian D, Athertya JS, Dwek S, et al. Achilles tendon and enthesis assessment using ultrashort echo time magnetic resonance imaging (UTE‐MRI) T1 and magnetization transfer (MT) modeling in psoriatic arthritis. NMR Biomed. 2024;37:e5040.
      Ma YJ, Zhu Y, Lu X, Carl M, Chang EY, Du J. Short T(2) imaging using a 3D double adiabatic inversion recovery prepared ultrashort echo time cones (3D DIR‐UTE‐cones) sequence. Magn Reson Med. 2018;79:2555‐2563.
      Ma YJ, Lu X, Carl M, et al. Accurate T(1) mapping of short T(2) tissues using a three‐dimensional ultrashort echo time cones actual flip angle imaging‐variable repetition time (3D UTE‐cones AFI‐VTR) method. Magn Reson Med. 2018;80:598‐608.
      Ma YJ, Zhao W, Wan L, et al. Whole knee joint T(1) values measured in vivo at 3T by combined 3D ultrashort echo time cones actual flip angle and variable flip angle methods. Magn Reson Med. 2019;81:1634‐1644.
      Sled JG, Pike GB. Quantitative interpretation of magnetization transfer in spoiled gradient echo MRI sequences. J Magn Reson. 2000;145:24‐36.
      Sled JG, Pike GB. Quantitative imaging of magnetization transfer exchange and relaxation properties in vivo using MRI. Magn Reson Med. 2001;46:923‐931.
      Ma YJ, Shao H, Du J, Chang EY. Ultrashort echo time magnetization transfer (UTE‐MT) imaging and modeling: magic angle independent biomarkers of tissue properties. NMR Biomed. 2016;29:1546‐1552.
      Biela E, Galas J, Lee B, Johnson GL, Darzynkiewicz Z, Dobrucki JW. Col‐F, a fluorescent probe for ex vivo confocal imaging of collagen and elastin in animal tissues. Cytometry A. 2013;83:533‐539.
      Montes GS, Junqueira LC. The use of the picrosirius‐polarization method for the study of the biopathology of collagen. Mem Inst Oswaldo Cruz. 1991;86:1‐11.
      Whittaker P, Kloner RA, Boughner DR, Pickering JG. Quantitative assessment of myocardial collagen with picrosirius red staining and circularly polarized light. Basic Res Cardiol. 1994;89:397‐410.
      Syha R, Martirosian P, Ketelsen D, et al. Magnetization transfer in human Achilles tendon assessed by a 3D ultrashort echo time sequence: quantitative examinations in healthy volunteers at 3T. Rofo. 2011;183:1043‐1050.
      von der Mark K. Localization of collagen types in tissues. Int Rev Connect Tissue Res. 1981;9:265‐324.
      Weinreb JH, Sheth C, Apostolakos J, et al. Tendon structure, disease, and imaging. Muscles Ligaments Tendons J. 2014;4:66‐73.
      Riley G. The pathogenesis of tendinopathy. A molecular perspective. Rheumatology (Oxford). 2004;43:131‐142.
      Haut RC, Lancaster RL, DeCamp CE. Mechanical properties of the canine patellar tendon: some correlations with age and the content of collagen. J Biomech. 1992;25:163‐173.
      Riley GP, Curry V, DeGroot J, et al. Matrix metalloproteinase activities and their relationship with collagen remodelling in tendon pathology. Matrix Biol. 2002;21:185‐195.
      Soslowsky LJ, Carpenter JE, DeBano CM, Banerji I, Moalli MR. Development and use of an animal model for investigations on rotator cuff disease. J Shoulder Elbow Surg. 1996;5:383‐392.
      Carpenter JE, Flanagan CL, Thomopoulos S, Yian EH, Soslowsky LJ. The effects of overuse combined with intrinsic or extrinsic alterations in an animal model of rotator cuff tendinosis. Am J Sports Med. 1998;26:801‐807.
      Puchtler H, Waldrop FS, Valentine LS. Polarization microscopic studies of connective tissue stained with picro‐sirius red FBA. Beitr Pathol. 1973;150:174‐187.
      Sritanyaratana N, Samsonov A, Mossahebi P, Wilson JJ, Block WF, Kijowski R. Cross‐relaxation imaging of human patellar cartilage in vivo at 3.0T. Osteoarthr Cartil. 2014;22:1568‐1576.
      Yarnykh VL. Fast macromolecular proton fraction mapping from a single off‐resonance magnetization transfer measurement. Magn Reson Med. 2012;68:166‐178.
      Ma YJ, Tadros A, Du J, Chang EY. Quantitative two‐dimensional ultrashort echo time magnetization transfer (2D UTE‐MT) imaging of cortical bone. Magn Reson Med. 2018;79:1941‐1949.
      Garcia M, Gloor M, Radue EW, et al. Fast high‐resolution brain imaging with balanced SSFP: interpretation of quantitative magnetization transfer towards simple MTR. Neuroimage. 2012;59:202‐211.
      Guo T, Ma YJ, High RA, et al. Assessment of an in vitro model of rotator cuff degeneration using quantitative magnetic resonance and ultrasound imaging with biochemical and histological correlation. Eur J Radiol. 2019;121:108706.
      Lee RR, Dagher AP. Low power method for estimating the magnetization transfer bound‐pool macromolecular fraction. J Magn Reson Imaging. 1997;7:913‐917.
      Kiefer C, Brockhaus L, Cattapan‐Ludewig K, et al. Multi‐parametric classification of Alzheimer's disease and mild cognitive impairment: the impact of quantitative magnetization transfer MR imaging. Neuroimage. 2009;48:657‐667.
      Cercignani M, Symms MR, Schmierer K, et al. Three‐dimensional quantitative magnetisation transfer imaging of the human brain. Neuroimage. 2005;27:436‐441.
      Chang EY, Du J, Chung CB. UTE imaging in the musculoskeletal system. J Magn Reson Imaging. 2015;41:870‐883.
      Zhu Y, Cheng X, Ma Y, et al. Rotator cuff tendon assessment using magic‐angle insensitive 3D ultrashort echo time cones magnetization transfer (UTE‐cones‐MT) imaging and modeling with histological correlation. J Magn Reson Imaging. 2018;48:160‐168.
      Yao W, Qu N, Lu Z, Yang S. The application of T1 and T2 relaxation time and magnetization transfer ratios to the early diagnosis of patellar cartilage osteoarthritis. Skeletal Radiol. 2009;38:1055‐1062.
    • Grant Information:
      BJ-2023-108 National High Level Hospital Clinical Research Funding; 81801673 National Natural Science Foundation of China
    • Contributed Indexing:
      Keywords: UTE; collagen degradation; magnetization transfer; rotator cuff tendinopathy
    • Accession Number:
      9007-34-5 (Collagen)
      EC 3.4.24.- (Collagenases)
    • Publication Date:
      Date Created: 20240510 Date Completed: 20240722 Latest Revision: 20240822
    • Publication Date:
      20240822
    • Accession Number:
      10.1002/mrm.30144
    • Accession Number:
      38725197