The Effect of Diabetic Retinopathy and Blood Glucose Regulation on Corneal Biomechanical Parameters.

Item request has been placed! ×
Item request cannot be made. ×
loading   Processing Request
  • Additional Information
    • Source:
      Publisher: Informa Healthcare Country of Publication: England NLM ID: 8104312 Publication Model: Print-Electronic Cited Medium: Internet ISSN: 1460-2202 (Electronic) Linking ISSN: 02713683 NLM ISO Abbreviation: Curr Eye Res Subsets: MEDLINE
    • Publication Information:
      Publication: London : Informa Healthcare
      Original Publication: London : IRL Press, [c1981-
    • Subject Terms:
    • Abstract:
      Purpose: The aim of this study was to evaluate the effects of different stages of diabetic retinopathy (DR) and metabolic control of blood glucose levels on corneal biomechanical parameters.
      Methods: Diabetic patients were categorized into three groups: no DR group, nonproliferative DR (NPDR) group, and proliferative DR (PDR) group. Of the 141 eyes examined, 40 belonged to the control group, 34 to no DR group, 34 to NPDR group, and 33 to PDR group. Using an Ocular Response Analyzer to measure corneal hysteresis (CH), corneal resistance factor (CRF), Goldmann-correlated intraocular pressure (IOPg), and corneal-compensated IOP (IOPcc). IOP was assessed using a Tono-Pen, while central corneal thickness (CCT) was determined using an ultrasonic pachymeter. HbA1c levels were also recorded. We conducted comparisons among these groups across biomechanical parameters and IOP (tonopen), and CCT, while also investigating the impact of HbA1c levels on these parameters.
      Results: Among any groups show a statistically significant difference in CCT, IOP (tonopen), CH, CRF, IOPg, and IOPcc. In diabetic patients, CRF, CTT, and IOPg values were significantly higher in those with HbA1c levels ≥ 7 mg/dl than in those with HbA1c levels < 7 mg/dl ( p  = 0.009, p  = 0.013, p  = 0.038), respectively, while there was no statistically significant difference in IOPcc, CH, and IOP (tonopen). Linear regression analysis showed that CH was positively associated with CCT ( p  < 0.001) and negatively associated with IOPcc ( p  < 0.001), while CRF was positively associated with CCT ( p  < 0.001), HbA1c ( p  < 0.05), and negatively associated with diagnosis of DR ( p  < 0.05).
      Conclusion: This study underscores the influence of metabolic control, as reflected by HbA1c levels, on corneal biomechanical parameters in diabetic patients, emphasizing the importance of monitoring and managing glycemic control in this population.
    • Contributed Indexing:
      Keywords: Diabetic retinopathy; HbA1c; corneal biomechanics; corneal hysteresis; corneal resistance factor
    • Accession Number:
      0 (Blood Glucose)
      0 (Glycated Hemoglobin)
      0 (hemoglobin A1c protein, human)
    • Publication Date:
      Date Created: 20240408 Date Completed: 20240717 Latest Revision: 20240717
    • Publication Date:
      20240717
    • Accession Number:
      10.1080/02713683.2024.2338219
    • Accession Number:
      38587365