Item request has been placed!
×
Item request cannot be made.
×
Processing Request
Digital Volumetric Measurements Based on 3D Scans of the Lower Limb: A Valid and Reproducible Method for Evaluation in Lymphedema Therapy.
Item request has been placed!
×
Item request cannot be made.
×
Processing Request
- Additional Information
- Source:
Publisher: Elsevier Country of Publication: Netherlands NLM ID: 8703941 Publication Model: Print-Electronic Cited Medium: Internet ISSN: 1615-5947 (Electronic) Linking ISSN: 08905096 NLM ISO Abbreviation: Ann Vasc Surg Subsets: MEDLINE
- Publication Information:
Publication: <2007->: Netherlands : Elsevier
Original Publication: Detroit : [Published by Expansion scientifique française for Annals of Vascular Surgery, Inc. and Association pour la promotion de la chirurgie vasculaire, Paris, c1986-
- Subject Terms:
- Abstract:
Background: Exact quantification of volumetric changes of the extremities is difficult and often error-prone. The aim of this study was to establish a standardized method based on 3-dimensional (3D) scans. Furthermore, this study tests the method in terms of reproducibility and evaluates volume changes after surgical therapy in patients suffering from lymphedema on the lower extremity.
Methods: 3D scans of the lower limb were performed with a mobile 3D scanner; "repeatability" and "interobserver reliability" of digital volumetry were tested. Furthermore, the method was applied on 31 patients suffering from chronic lymphedema.
Results: Calculations of repeatability of the volume based on 20 3D scans of the same lower leg showed a mean volume of 2.488 ± 0.011 liters (range: 2.470-2.510). The mean volume of the different examiners did not differ significantly (F (2,18) = 1.579, P = 0.233). The paired t-test showed a significant mean volume decrease of 375 mL (95% confidence interval = 245/505 mL) between pretreatment and post-treatment (t (30) = 5.892, P < 0.001).
Conclusions: 3D volumetry is a noninvasive, easy, and quick method to assess volume changes of the lower leg. Other than the low costs, it is reproducible and precise and therefore ideal for evolution of therapy in lymphedema.