Strong Diagnostic Performance of Single Energy 256-row Multidetector Computed Tomography with Deep Learning Image Reconstruction in the Assessment of Myocardial Fibrosis.

Item request has been placed! ×
Item request cannot be made. ×
loading   Processing Request
  • Additional Information
    • Source:
      Publisher: Japanese Society of Internal Medicine Country of Publication: Japan NLM ID: 9204241 Publication Model: Print-Electronic Cited Medium: Internet ISSN: 1349-7235 (Electronic) Linking ISSN: 09182918 NLM ISO Abbreviation: Intern Med Subsets: MEDLINE
    • Publication Information:
      Original Publication: Tokyo, Japan : Japanese Society of Internal Medicine, [1992-
    • Subject Terms:
    • Abstract:
      Objective Although magnetic resonance imaging (MRI) is the gold standard for evaluating abnormal myocardial fibrosis and extracellular volume (ECV) of the left ventricular myocardium (LVM), a similar evaluation has recently become possible using computed tomography (CT). In this study, we investigated the diagnostic accuracy of a new 256-row multidetector CT with a low tube-voltage single energy scan and deep-learning-image reconstruction (DLIR) in detecting abnormal late enhancement (LE) in LVM. Methods We evaluated the diagnostic performance of CT for detecting LE in LVM and compared the results with those of MRI as a reference. We also measured the ECV of the LVM on CT and compared the results with those on MRI. Materials We analyzed 50 consecutive patients who underwent cardiac CT, including a late-phase scan and MRI, within three months of suspected cardiomyopathy. All patients underwent 256-slice CT (Revolution APEX; GE Healthcare, Waukesha, USA) with a low tube-voltage (70 kV) single energy scan and DLIR for a late-phase scan. Results In patient- and segment-based analyses, the sensitivity, specificity, and accuracy of detection of LE on CT were 94% and 85%, 100% and 95%, and 96% and 93%, respectively. The ECV of LVM per patient on CT and MRI was 33.0±6.2% and 35.9±6.1%, respectively. These findings were extremely strongly correlated, with a correlation coefficient of 0.87 (p<0.0001). The effective radiation dose on late-phase scanning was 2.4±0.9 mSv. Conclusion The diagnostic performance of 256-row multislice CT with a low tube voltage and DLIR for detecting LE and measuring ECV in LVM is credible.
    • References:
      Radiology. 2018 Sep;288(3):682-691. (PMID: 29989514)
      Eur J Radiol. 2022 Aug;153:110386. (PMID: 35661458)
      Circulation. 1999 Nov 9;100(19):1992-2002. (PMID: 10556226)
      Radiology. 2012 Sep;264(3):876-83. (PMID: 22771879)
      Int J Cardiol. 2011 Jun 2;149(2):e90-e93. (PMID: 21474191)
      JACC Cardiovasc Imaging. 2023 Feb;16(2):175-188. (PMID: 36444769)
      Eur J Heart Fail. 2015 Sep;17(9):884-92. (PMID: 26222508)
      JACC Cardiovasc Imaging. 2018 Jan;11(1):48-59. (PMID: 28624408)
      Circ J. 2014;78(4):832-4. (PMID: 24614511)
      Circulation. 2002 Jan 29;105(4):539-42. (PMID: 11815441)
      Int J Cardiol. 2017 Feb 1;228:375-379. (PMID: 27866030)
      Circ J. 2020 Aug 25;84(9):1610-1671. (PMID: 32830187)
      Eur Radiol. 2015 Feb;25(2):575-84. (PMID: 25316053)
      Intern Med. 2020 Sep 1;59(17):2095-2103. (PMID: 32493851)
      JACC Cardiovasc Imaging. 2016 Sep;9(9):1046-1055. (PMID: 27450871)
      Br J Radiol. 2006 Dec;79(948):968-80. (PMID: 17213302)
      J Cardiovasc Magn Reson. 2011 Nov 28;13:75. (PMID: 22123333)
      Circulation. 1984 Aug;70(2):217-25. (PMID: 6733878)
      Int J Cardiovasc Imaging. 2015 Dec;31 Suppl 2:177-85. (PMID: 26202159)
      Heart Vessels. 2023 May;38(5):721-730. (PMID: 36534159)
      Med Phys. 2000 May;27(5):838-44. (PMID: 10841385)
      Radiol Med. 2020 Feb;125(2):128-136. (PMID: 31784926)
      Radiographics. 2009 Jan-Feb;29(1):89-103. (PMID: 19168838)
      Int J Cardiol. 2013 Oct 03;168(3):2811-5. (PMID: 23618429)
      Heart Vessels. 2023 Feb;38(2):185-194. (PMID: 35963911)
      J Comput Assist Tomogr. 2011 Jan-Feb;35(1):141-7. (PMID: 21245699)
      Int J Cardiovasc Imaging. 2017 Oct;33(10):1609-1618. (PMID: 28409258)
      Eur Radiol. 2024 Feb;34(2):1016-1025. (PMID: 37597032)
    • Contributed Indexing:
      Keywords: computed tomography; deep leaning image reconstruction; late enhancement; left ventricular myocardium
    • Publication Date:
      Date Created: 20240212 Date Completed: 20240916 Latest Revision: 20241018
    • Publication Date:
      20241018
    • Accession Number:
      PMC11473283
    • Accession Number:
      10.2169/internalmedicine.2615-23
    • Accession Number:
      38346744