Extubation failure: Upper airway obstruction by chewing gum. A case report.
Item request has been placed!
×
Item request cannot be made.
×
Processing Request
- Additional Information
- Source:
Publisher: Elsevier España Country of Publication: Spain NLM ID: 101778594 Publication Model: Print-Electronic Cited Medium: Internet ISSN: 2341-1929 (Electronic) Linking ISSN: 23411929 NLM ISO Abbreviation: Rev Esp Anestesiol Reanim (Engl Ed) Subsets: MEDLINE
- Publication Information:
Original Publication: Barcelona : Elsevier España, 2015-
- Subject Terms:
- Abstract:
Extubation failure can result from different complications, mostly well described in the literature such as laryngeal edema. Airway obstruction by foreign bodies is a less frequent and unexpected complication and its detection remains a challenge to healthcare professionals. In this case-report, we describe a patient admitted in an intensive care unit following a motor vehicle accident and who underwent an extubation failure and tracheostomy placement due to a misdiagnosed obstruction of a foreign body in the upper airway. Thus, screening of foreign bodies should be considered with a careful interpretation of medical imagery and clinical evaluation in these patients. Finally, cuff leak test, ultrasonography and videolaryngoscopy can be important adjuvants to the identification of suspected foreign bodies.
(Copyright © 2024. Publicado por Elsevier España, S.L.U.)
- Contributed Indexing:
Keywords: Airway foreign body obstruction; Aspiración; Aspiration; Chewing gum; Chicle; Cuidados intensivos; Extubation failure; Fallo de la extubación; Intensive care; Obstrucción de la vía aérea por cuerpo extraño