Chairside 3-D printed impression trays: a new approach to increase the accuracy of conventional implant impression taking? An in vitro study.
Item request has been placed!
×
Item request cannot be made.
×
Processing Request
- Additional Information
- Source:
Publisher: Springer Country of Publication: Germany NLM ID: 101676532 Publication Model: Electronic Cited Medium: Internet ISSN: 2198-4034 (Electronic) Linking ISSN: 21984034 NLM ISO Abbreviation: Int J Implant Dent Subsets: MEDLINE
- Publication Information:
Original Publication: Heidelberg : Springer, [2015]-
- Subject Terms:
- Abstract:
Purpose: A high transfer accuracy of the intraoral implant position to a model is required, to manufacture implant-supported restorations. However, clinically relevant deviations persist between the intraoral implant position and the model obtained, even for the benchmark conventional custom implant impressions with polyether. Thus, new approaches using 3-D printed impression trays may increase the transfer accuracy of implant impressions. The ability to adjust parameters such as the thickness of the layers and the influence of the openings in the impression tray could potentially affect accuracy.
Methods: Four different types of impression trays (n = 10 for each group) for the conventional impression technique were investigated: conventional custom impression tray, customized foil tray, chairside 3-D printed impression tray with the SHERA system, and the Primeprint system using an implant master model with four implants in the posterior region and a reference cube. After plaster model casting, all models were measured using a coordinate measuring machine, and the deviation from the reference dataset was determined. A statistical ANOVA analysis was performed (p < 0.05).
Results: Chairside 3-D printed impression trays showed the best results, followed by conventional custom impression trays. Implant impressions obtained using a customized foil tray exhibited the lowest accuracy. Statistically significant differences were observed between 3-D printed impression trays and conventional custom impression and customized foil trays (p < 0.05). Whereas, the implant position did not have any significant influence on accuracy (p > 0.05).
Conclusions: Chairside 3-D printed impression trays significantly increase the transfer accuracy for implant impression taking.
(© 2023. The Author(s).)
- References:
J Prosthodont. 2020 Oct;29(8):660-678. (PMID: 32613641)
Quintessence Int. 2014 Jan;45(1):39-51. (PMID: 24392494)
J Prosthet Dent. 2014 Oct;112(4):843-8. (PMID: 24787129)
Clin Oral Investig. 2020 Feb;24(2):735-745. (PMID: 31134345)
Int J Oral Maxillofac Implants. 2010 May-Jun;25(3):506-15. (PMID: 20556249)
Clin Oral Investig. 2023 Jun;27(6):2465-2481. (PMID: 37017759)
J Prosthet Dent. 2015 Aug;114(2):185-92.e1. (PMID: 25935089)
Int J Prosthodont. 2021 Jan-Feb;34(1):109-117. (PMID: 33570526)
J Prosthet Dent. 2008 Oct;100(4):285-91. (PMID: 18922257)
Sci Rep. 2016 Jan 14;6:19207. (PMID: 26763620)
J Prosthet Dent. 2022 Sep;128(3):396-403. (PMID: 33593675)
Med Oral Patol Oral Cir Bucal. 2019 Jan 1;24(1):e89-e95. (PMID: 30573714)
J Clin Med. 2022 Jan 25;11(3):. (PMID: 35160045)
J Prosthet Dent. 2023 Feb;129(2):354-362. (PMID: 34112521)
Int J Implant Dent. 2021 Jul 27;7(1):97. (PMID: 34312701)
Int J Oral Maxillofac Implants. 2019 May 20;34(4):1007–1014. (PMID: 31107937)
Int J Oral Maxillofac Implants. 2012 Nov-Dec;27(6):e96-101. (PMID: 23189316)
Schweiz Monatsschr Zahnmed. 1994;104(6):756-69. (PMID: 8042025)
Materials (Basel). 2021 Jan 21;14(3):. (PMID: 33494397)
Clin Implant Dent Relat Res. 2015 Oct;17 Suppl 2:e751-64. (PMID: 25828851)
Br Dent J. 2015 Dec;219(11):521-9. (PMID: 26657435)
Int J Comput Dent. 2019;22(3):231-237. (PMID: 31463487)
Scanning. 2021 Jul 17;2021:9950131. (PMID: 34367410)
Dent Mater J. 2020 Jun 5;39(3):345-354. (PMID: 32037387)
Int J Comput Dent. 2021 Jun 4;24(2):157-164. (PMID: 34085501)
J Contemp Dent Pract. 2018 Aug 1;19(8):974-981. (PMID: 30150500)
J Prosthodont Res. 2018 Apr;62(2):245-251. (PMID: 29191609)
J Clin Exp Dent. 2020 Feb 01;12(2):e187-e192. (PMID: 32071701)
Int J Prosthodont. 2021 Mar-Apr;34(2):254-260. (PMID: 33882570)
Eur J Oral Implantol. 2017;10 Suppl 1:121-138. (PMID: 28944373)
Clin Oral Implants Res. 2021 Apr;32(4):460-469. (PMID: 33469983)
Int J Oral Maxillofac Implants. 2014 Jul-Aug;29(4):869-80. (PMID: 25032767)
J Dent. 2016 Dec;55:68-74. (PMID: 27717754)
Int J Oral Maxillofac Implants. 2022 Nov-Dec;37(6):1119-1137. (PMID: 36450017)
Clin Oral Investig. 2021 Jul;25(7):4635-4642. (PMID: 33442777)
Sci Rep. 2017 Nov 2;7(1):14958. (PMID: 29097699)
Clin Oral Investig. 2016 Sep;20(7):1487-94. (PMID: 26454734)
Int J Implant Dent. 2021 Jul 30;7(1):75. (PMID: 34327601)
J Oral Implantol. 2013 Feb;39(1):23-9. (PMID: 23402356)
J Prosthet Dent. 2016 Aug;116(2):184-190.e12. (PMID: 26946916)
Clin Oral Implants Res. 2022 Jun;33(6):573-585. (PMID: 35527511)
Int J Environ Res Public Health. 2018 Jul 27;15(8):. (PMID: 30060540)
Int J Oral Maxillofac Implants. 2014 Jul-Aug;29(4):836-45. (PMID: 25032763)
J Med Eng. 2013;2013:265412. (PMID: 27017916)
Int J Implant Dent. 2020 Oct 10;6(1):54. (PMID: 33037508)
J Clin Med. 2020 Mar 04;9(3):. (PMID: 32143433)
J Prosthet Dent. 2021 Mar;125(3):470-478. (PMID: 32386912)
- Contributed Indexing:
Keywords: 3-D printing; CAD–CAM; Dental implants; Dental impression technique; Full-arch implant case; Impression accuracy; Manufactured materials; Open impression technique; Precision; Trueness
- Accession Number:
0 (Dental Impression Materials)
0 (Dental Implants)
- Publication Date:
Date Created: 20231205 Date Completed: 20231207 Latest Revision: 20231208
- Publication Date:
20231215
- Accession Number:
PMC10697909
- Accession Number:
10.1186/s40729-023-00516-9
- Accession Number:
38052992
No Comments.