Impact of the inferior vena cava morphology on fluid dynamics of the hepatic veins.

Item request has been placed! ×
Item request cannot be made. ×
loading   Processing Request
  • Additional Information
    • Source:
      Publisher: Springer International Country of Publication: Japan NLM ID: 9204360 Publication Model: Print-Electronic Cited Medium: Internet ISSN: 1436-2813 (Electronic) Linking ISSN: 09411291 NLM ISO Abbreviation: Surg Today Subsets: MEDLINE
    • Publication Information:
      Original Publication: Tokyo : Springer International, c1992-
    • Subject Terms:
    • Abstract:
      We reported previously that a large vertical interval between the hepatic segment of the inferior vena cava (IVC) and right atrium (RA), referred to as the IVC-RA gap, was associated with more intraoperative bleeding during hemi-hepatectomy. We conducted a computational fluid dynamics (CFD) study to clarify the impact of fluid dynamics resulting from morphologic variations around the liver. The subjects were 10 patients/donors with a large IVC-RA gap and 10 patients/donors with a small IVC-RA gap. Three-dimensional reconstructions of the IVC and hepatic vessels were created from CT images for the CFD study. Median pressure in the middle hepatic vein was significantly higher in the large-gap group than in the small-gap group (P = 0.008). Differences in hepatic vein pressure caused by morphologic variation in the IVC might be one of the mechanisms of intraoperative bleeding from the hepatic veins.
      (© 2023. The Author(s) under exclusive licence to Springer Nature Singapore Pte Ltd.)
    • References:
      Sakamoto K, Iwamoto Y, Ogawa K, Tamura K, Nishi Y, Uraoka M, et al. Unification venoplasty during two versus one venous reconstruction: computational fluid dynamics study. J Hepatobiliary Pancreat Sci. 2022. https://doi.org/10.1002/jhbp.1280 . (Epub ahead of print. PMID: 36401822). (PMID: 10.1002/jhbp.128036401822)
      Ito T, Ogiso S, Nakamura M, Oshima Y, Horie H, Wakama S, et al. Fluid analysis unveils hepatic venous outflow obstruction and its negative impact on posttransplant graft regeneration. Liver Transpl. 2023. https://doi.org/10.1097/LVT.0000000000000086 . (Epub ahead of print. PMID: 36724445). (PMID: 10.1097/LVT.000000000000008637729520)
      Sakamoto K, Ogawa K, Matsui T, Utsunomiya T, Honjo M, Ueno Y, et al. Vertical interval between hepatic segment of inferior vena cava and right atrium predicts intraoperative blood loss during hemi-hepatectomy. J Hepatobiliary Pancreat Sci. 2020;27(2):90–100. https://doi.org/10.1002/jhbp.689 . (Epub 2019 Nov 26 PMID: 31633293). (PMID: 10.1002/jhbp.68931633293)
      Nanashima A, Tanoue Y, Sakae T, Tsuneyoshi I, Hiyoshi M, Imamura N, et al. Relationship between hepatic venous anatomy and hepatic venous blood loss during hepatectomy. Surg Today. 2021;51(12):1953–68. https://doi.org/10.1007/s00595-021-02314-5 . (Epub 2021 Jun 15 PMID: 34129114). (PMID: 10.1007/s00595-021-02314-534129114)
      Rijnberg FM, van der Woude SFS, Hazekamp MG, van den Boogaard PJ, Lamb HJ, de Terol Espinosa Los Monteros C, et al. Extracardiac conduit adequacy along the respiratory cycle in adolescent Fontan patients. Eur J Cardiothorac Surg. 2022;62(1):ezab478. https://doi.org/10.1093/ejcts/ezab478 . (PMID: 34747442 PMCID: PMC9257669). (PMID: 10.1093/ejcts/ezab47834747442)
      Ukere A, Meisner S, Greiwe G, Opitz B, Benten D, Nashan B, et al. The influence of PEEP and positioning on central venous pressure and venous hepatic hemodynamics in patients undergoing liver resection. J Clin Monit Comput. 2017;31(6):1221–8. https://doi.org/10.1007/s10877-016-9970-1 . (Epub 2016 Dec 23 PMID: 28012012). (PMID: 10.1007/s10877-016-9970-128012012)
      Yoneda G, Katagiri S, Yamamoto M. Reverse Trendelenburg position is a safer technique for lowering central venous pressure without decreasing blood pressure than clamping of the inferior vena cava below the liver. J Hepatobiliary Pancreat Sci. 2015;22(6):463–6. https://doi.org/10.1002/jhbp.229 . (Epub 2015 Mar 12 PMID: 25763776). (PMID: 10.1002/jhbp.22925763776)
      Liu TS, Shen QH, Zhou XY, Shen X, Lai L, Hou XM, et al. Application of controlled low central venous pressure during hepatectomy: a systematic review and meta-analysis. J Clin Anesth. 2021;75:110467. https://doi.org/10.1016/j.jclinane.2021.110467 . (Epub 2021 Aug 1 PMID: 34343737). (PMID: 10.1016/j.jclinane.2021.11046734343737)
    • Grant Information:
      21K16450 JSPS KAKENHI
    • Contributed Indexing:
      Keywords: Computational fluid dynamics; Hepatic vein; Inferior vena cava; Right atrium; Venous pressure
    • Publication Date:
      Date Created: 20230729 Date Completed: 20240123 Latest Revision: 20240123
    • Publication Date:
      20240123
    • Accession Number:
      10.1007/s00595-023-02733-6
    • Accession Number:
      37516666