Item request has been placed!
×
Item request cannot be made.
×
Processing Request
Comparison of Biological Effectiveness of Carbon-Ion Beams in Japan and Germany
Item request has been placed!
×
Item request cannot be made.
×
Processing Request
- Author(s): Uzawa, Akiko1; Ando, Koichi2 ; Koike, Sachiko1; Furusawa, Yoshiya1; Matsumoto, Yoshitaka1; Takai, Nobuhiko1; Hirayama, Ryoichi1; Watanabe, Masahiko1; Scholz, Michael3; Elsässer, Thilo3; Peschke, Peter4
- Source:
International Journal of Radiation Oncology, Biology, Physics. Apr2009, Vol. 73 Issue 5, p1545-1551. 7p.
- Subject Terms:
- Additional Information
- Subject Terms:
- Abstract:
Purpose: To compare the biological effectiveness of 290 MeV/amu carbon-ion beams in Chiba, Japan and in Darmstadt, Germany, given that different methods for beam delivery are used for each. Methods and Materials: Murine small intestine and human salivary gland tumor (HSG) cells exponentially growing in vitro were irradiated with 6-cm width of spread-out Bragg peaks (SOBPs) adjusted to achieve nearly identical beam depth–dose profiles at the Heavy-Ion Medical Accelerator in Chiba, and the SchwerIonen Synchrotron in Darmstadt. Cell kill efficiencies of carbon ions were measured by colony formation for HSG cells and jejunum crypts survival in mice. Cobalt-60 γ rays were used as the reference radiation. Isoeffective doses at given survivals were used for relative biological effectiveness (RBE) calculations and interinstitutional comparisons. Results: Isoeffective D10 doses (mean ± standard deviation) of HSG cells ranged from 2.37 ± 0.14 Gy to 3.47 ± 0.19 Gy for Chiba and from 2.31 ± 0.11 Gy to 3.66 ± 0.17 Gy for Darmstadt. Isoeffective D10 doses of gut crypts after single doses ranged from 8.25 ± 0.17 Gy to 10.32 ± 0.14 Gy for Chiba and from 8.27 ± 0.10 Gy to 10.27 ± 0.27 Gy for Darmstadt, whereas isoeffective D30 doses after three fractionated doses were 9.89 ± 0.17 Gy through 13.70 ± 0.54 Gy and 10.14 ± 0.20 Gy through 13.30 ± 0.41 Gy for Chiba and Darmstadt, respectively. Overall difference of RBE between the two facilities was 0–5% or 3–7% for gut crypt survival or HSG cell kill, respectively. Conclusion: The carbon-ion beams at the National Institute of Radiological Sciences in Chiba, Japan and the Gesellschaft für Schwerionenforschung in Darmstadt, Germany are biologically identical after single and daily fractionated irradiation. [Copyright &y& Elsevier]
- Abstract:
Copyright of International Journal of Radiation Oncology, Biology, Physics is the property of Pergamon Press - An Imprint of Elsevier Science and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
No Comments.