Item request has been placed!
×
Item request cannot be made.
×

Processing Request
Comparability of a Blood-Pressure-Monitoring Smartphone Application with Conventional Measurements-A Pilot Study.
Item request has been placed!
×
Item request cannot be made.
×

Processing Request
- Additional Information
- Source:
Publisher: MDPI AG Country of Publication: Switzerland NLM ID: 101658402 Publication Model: Electronic Cited Medium: Print ISSN: 2075-4418 (Print) Linking ISSN: 20754418 NLM ISO Abbreviation: Diagnostics (Basel) Subsets: PubMed not MEDLINE
- Publication Information:
Original Publication: Basel, Switzerland : MDPI AG, [2011]-
- Abstract:
(1) Background: New cuffless technologies attempting blood-pressure measurements (BPM) offer possibilities to improve hypertension awareness and control. The aim of this study was to compare a smartphone application (app)-based algorithm with office BPM (OBPM). (2) Methods: We included consecutive patients with an indication for ambulatory BPM. The smartphone app (RIVA digital) acquired the pulse wave in the fingers’ arterial bed using the phone’s camera and estimated BP based on photoplethysmographic (PPG) waveforms. Measurements were alternatingly taken with an oscillometric cuff-based device and smartphone BPM (AppBP) on two consecutive days. AppBP were calibrated to the first OBPM. Each AppBP was compared to its CuffBP (mean of the previous/following OBPM). (3) Results: 50 participants were included, resulting in 50 AppBP values on Day 1 and 33 on Day 2 after exclusion of 225 AppBP due to insufficient quality. The mean ± SD of the differences between AppBP and CuffBP was 0.7 ± 9.4/1.0 ± 4.5 mmHg (p-value 0.739/0.201) on Day 1 and 2.6 ± 8.2/1.3 ± 4.1 mmHg (p-value 0.106/0.091) on Day 2 for systolic/diastolic values, respectively. There were no significant differences between the deviations on Day 1 and Day 2 (p-value 0.297/0.533 for systolic/diastolic values). Overall, there were 10 (12%) systolic measurement pairs differing by >15 mmHg. (4) Conclusions: In this pilot evaluation, the RIVA Digital app shows promising results when compared to oscillometric cuff-based measurements, especially regarding diastolic values. Its differences between AppBP−CuffBP have a good stability one day after calibration. Before clinical use, signal acquisition needs improvement and the algorithm needs to undergo formal validation against a gold-standard BPM method.
- References:
J Clin Hypertens (Greenwich). 2022 May;24(5):582-590. (PMID: 35393677)
Blood Press Monit. 2011 Apr;16(2):96-8. (PMID: 21412074)
Sci Rep. 2018 May 8;8(1):7298. (PMID: 29740088)
Am Heart J. 2021 Mar;233:102-108. (PMID: 33321118)
Korean Circ J. 2022 Mar;52(3):198-204. (PMID: 35257532)
Circ Cardiovasc Imaging. 2019 Aug;12(8):e008857. (PMID: 31382766)
Blood Press Monit. 2021 Dec 1;26(6):441-448. (PMID: 34139747)
J Hypertens. 2019 Mar;37(3):459-466. (PMID: 30702492)
Nat Rev Dis Primers. 2018 Mar 22;4:18014. (PMID: 29565029)
Sci Rep. 2020 Oct 20;10(1):17827. (PMID: 33082436)
J Hypertens. 1990 Jul;8(7):607-19. (PMID: 2168451)
JMIR Mhealth Uhealth. 2019 May 28;7(5):e13645. (PMID: 31140434)
Lancet. 2016 Mar 5;387(10022):957-967. (PMID: 26724178)
Blood Press Monit. 2010 Feb;15(1):23-38. (PMID: 20110786)
N Engl J Med. 1978 Oct 5;299(14):741-4. (PMID: 692548)
Clin Hypertens. 2021 Jan 25;27(1):4. (PMID: 33494809)
J Hum Hypertens. 2021 May;35(5):455-461. (PMID: 32461579)
Anesth Analg. 2020 May;130(5):1222-1233. (PMID: 32287129)
Hypertension. 2020 Sep;76(3):640-650. (PMID: 32755418)
Sensors (Basel). 2021 May 19;21(10):. (PMID: 34069396)
Nat Rev Nephrol. 2020 Apr;16(4):223-237. (PMID: 32024986)
JAMA Intern Med. 2016 May 1;176(5):700-2. (PMID: 26938174)
J Clin Hypertens (Greenwich). 2006 Jan;8(1):57-60. (PMID: 16407691)
Lancet. 2002 Dec 14;360(9349):1903-13. (PMID: 12493255)
Eur Heart J. 2019 Jul 1;40(25):2006-2017. (PMID: 31041440)
Eur Heart J. 2018 Sep 1;39(33):3021-3104. (PMID: 30165516)
Sci Transl Med. 2018 Mar 7;10(431):. (PMID: 29515001)
BMJ. 2019 Apr 12;365:l1657. (PMID: 30979699)
Diagnostics (Basel). 2021 Feb 03;11(2):. (PMID: 33546474)
Hypertension. 2018 Jun;71(6):1164-1169. (PMID: 29632098)
Hypertension. 2018 Mar;71(3):368-374. (PMID: 29386350)
J Clin Hypertens (Greenwich). 2018 Jul;20(7):1089-1091. (PMID: 30003695)
J Hum Hypertens. 2015 Apr;29(4):247-53. (PMID: 25273858)
Lancet. 2017 Dec 9;390(10112):2549-2558. (PMID: 29102084)
Ann Med. 2010 Jul;42(5):371-86. (PMID: 20504241)
- Grant Information:
NA Swiss Center for Electronics and Microtechnology (Switzerland)
- Contributed Indexing:
Keywords: arterial hypertension; blood-pressure measurement; blood-pressure monitoring; diagnostic techniques; monitoring; new technologies; smartphone application
- Publication Date:
Date Created: 20220325 Latest Revision: 20240825
- Publication Date:
20240826
- Accession Number:
PMC8947665
- Accession Number:
10.3390/diagnostics12030749
- Accession Number:
35328302
No Comments.