Use of a circular fixator construct to facilitate closed reduction and percutaneous stabilization of a distal femoral physeal fracture in a dog.

Item request has been placed! ×
Item request cannot be made. ×
loading   Processing Request
  • Additional Information
    • Source:
      Publisher: Faculty of Veterinary Medicine, University of Tripoli Country of Publication: Libya NLM ID: 101653182 Publication Model: Print-Electronic Cited Medium: Internet ISSN: 2218-6050 (Electronic) Linking ISSN: 22186050 NLM ISO Abbreviation: Open Vet J Subsets: MEDLINE
    • Publication Information:
      Publication: Nov. 2016 -: Tripoli, Libya : Faculty of Veterinary Medicine, University of Tripoli
      Original Publication: Tripoli, Libya : Faculty of Veterinary Medicine, University of Tripoli : National Authority for Scientific Research
    • Subject Terms:
    • Abstract:
      Background: Fractures of the distal femoral physis are the most common physeal fracture sustained by skeletally immature dogs. Reduction and stabilization of these fractures can sometimes be achieved through closed reduction, primarily in fractures that are nominally displaced. Circular external fixator constructs have been used to assist in indirect, closed reduction of fractures at other anatomic locations in dogs and this report describes application of this method to reduce a displaced Salter-Harris type II fracture of the distal femur in a 1-year-old dog.
      Case Description: A 1-year-old female spayed Akita was referred for treatment of a Salter-Harris type II fracture of the right distal femur. The epiphyseal segment was laterally and slightly caudally displaced. Multiple attempts to manually reduce the fracture during surgery were unsuccessful, so a two-ring circular external fixator construct was applied to facilitate distraction and reduction. The construct was applied by placing a medial-to-lateral Kirschner wire in both the mid-femoral diaphysis and in the distal femoral epiphysis. Distraction of the construct provided sufficient separation of the fracture segments to facilitate near anatomic reduction. The fracture was stabilized with two percutaneously placed Steinmann pins placed in Rush fashion. Radiographic union was confirmed 5 weeks after surgery. The dog was not lame and was bearing more weight on the right pelvic limb, as assessed using force plate analysis, 9 months following surgery. Goniometric measurements of stifle range of motion and thigh muscle circumference were similar between the pelvic limbs.
      Conclusion: Application of a two-ring circular construct would appear to be useful to facilitate closed reduction and percutaneous stabilization of distal femoral physeal fractures.
      Competing Interests: The corresponding author teaches continuing education courses for IMEX Veterinary Inc. The other authors have no conflict of interest to declare relative to the work presented here.
    • References:
      Vet Surg. 1999 Sep-Oct;28(5):315-21. (PMID: 10493635)
      Vet Surg. 2017 Jan;46(1):103-110. (PMID: 27925240)
      J Am Acad Orthop Surg. 1994 Oct;2(5):247-254. (PMID: 10709016)
      J Am Vet Med Assoc. 2012 Sep 15;241(6):744-53. (PMID: 22947157)
      Vet Surg. 2017 Oct;46(7):971-980. (PMID: 28703857)
      Aust Vet J. 2017 May;95(5):161-166. (PMID: 28444758)
      Vet Comp Orthop Traumatol. 2012;25(5):410-7. (PMID: 22828876)
      Vet Clin North Am Small Anim Pract. 2012 Sep;42(5):963-74, vi. (PMID: 23040302)
      Vet Clin North Am Small Anim Pract. 2020 Jan;50(1):23-47. (PMID: 31635912)
      J Am Anim Hosp Assoc. 2003 Sep-Oct;39(5):479-98. (PMID: 14518657)
      J Am Vet Med Assoc. 1983 Apr 1;182(7):708-10. (PMID: 6841256)
      Vet Clin North Am Small Anim Pract. 2020 Jan;50(1):135-153. (PMID: 31635915)
      Vet Surg. 2013 Jan;42(1):19-27. (PMID: 23181825)
      J Bone Joint Surg Br. 2005 Jun;87(6):829-36. (PMID: 15911668)
      Vet Surg. 2010 Dec;39(8):905-8. (PMID: 21133952)
    • Contributed Indexing:
      Keywords: Circular fixator; Closed reduction; Dogs; Femur; Salter-Harris fracture
    • Publication Date:
      Date Created: 20210426 Date Completed: 20211004 Latest Revision: 20211004
    • Publication Date:
      20231215
    • Accession Number:
      PMC8057213
    • Accession Number:
      10.4314/ovj.v11i1.13
    • Accession Number:
      33898288