Rapid, Sensitive, and Specific Severe Acute Respiratory Syndrome Coronavirus 2 Detection: A Multicenter Comparison Between Standard Quantitative Reverse-Transcriptase Polymerase Chain Reaction and CRISPR-Based DETECTR.

Item request has been placed! ×
Item request cannot be made. ×
loading   Processing Request
  • Additional Information
    • Source:
      Publisher: Oxford University Press Country of Publication: United States NLM ID: 0413675 Publication Model: Print Cited Medium: Internet ISSN: 1537-6613 (Electronic) Linking ISSN: 00221899 NLM ISO Abbreviation: J Infect Dis Subsets: MEDLINE
    • Publication Information:
      Publication: Jan. 2011- : Oxford : Oxford University Press
      Original Publication: 1904-2010 : Chicago, IL : University of Chicago Press
    • Subject Terms:
    • Abstract:
      Background: Recent advances in CRISPR-based diagnostics suggest that DETECTR, a combination of reverse-transcriptase loop-mediated isothermal amplification (RT-LAMP) and subsequent Cas12 bystander nuclease activation by amplicon-targeting ribonucleoprotein complexes, could be a faster and cheaper alternative to quantitative reverse-transcription polymerase chain reaction (qRT-PCR) without sacrificing sensitivity and/or specificity.
      Methods: In this study, we compare DETECTR with qRT-PCR to diagnose coronavirus disease 2019 on 378 patient samples. Patient sample dilution assays suggest a higher analytical sensitivity of DETECTR compared with qRT-PCR; however, this was not confirmed in this large patient cohort, where we report 95% reproducibility between the 2 tests.
      Results: These data showed that both techniques are equally sensitive in detecting severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) providing additional value of DETECTR to the currently used qRT-PCR platforms. For DETECTR, different guide ribonucleic acids can be used simultaneously to obviate negative results due to mutations in N-gene. Lateral flow strips, suitable as a point-of-care test, showed a 100% correlation to the high-throughput DETECTR assay. More importantly, DETECTR was 100% specific for SARS-CoV-2 relative to other human coronaviruses.
      Conclusions: Because there is no need for specialized equipment, DETECTR could be rapidly implemented as a complementary technically independent approach to qRT-PCR thereby increasing the testing capacity of medical microbiological laboratories and relieving the existent PCR platforms for routine non-SARS-CoV-2 diagnostic testing.
      (© The Author(s) 2020. Published by Oxford University Press for the Infectious Diseases Society of America. All rights reserved. For permissions, e-mail: [email protected].)
    • Contributed Indexing:
      Keywords: COVID-19; DETECTR; SARS-CoV-2; qRT-PCR
    • Accession Number:
      0 (RNA, Viral)
    • Subject Terms:
      LAMP assay
    • Publication Date:
      Date Created: 20210203 Date Completed: 20210225 Latest Revision: 20210912
    • Publication Date:
      20231215
    • Accession Number:
      PMC7665660
    • Accession Number:
      10.1093/infdis/jiaa641
    • Accession Number:
      33535237