Item request has been placed!
×
Item request cannot be made.
×
Processing Request
In vitro comparison of the accuracy of four intraoral scanners and three conventional impression methods for two neighboring implants.
Item request has been placed!
×
Item request cannot be made.
×
Processing Request
- Additional Information
- Source:
Publisher: Public Library of Science Country of Publication: United States NLM ID: 101285081 Publication Model: eCollection Cited Medium: Internet ISSN: 1932-6203 (Electronic) Linking ISSN: 19326203 NLM ISO Abbreviation: PLoS One Subsets: MEDLINE
- Publication Information:
Original Publication: San Francisco, CA : Public Library of Science
- Subject Terms:
- Abstract:
Purpose: To determine whether the accuracy of two-implant model impressions taken with optical scanners was inferior to that of those taken with elastomeric materials.
Materials and Methods: Impressions of a resin reference model with two almost parallel implants were taken using three elastomeric impressions (closed tray technique, open tray nonsplinted technique and open tray splinted technique) and scanned with four optical scanners (CEREC Omnicam, 3M True Definition Scanner, 3Shape TRIOS3 and Carestream CS 3600). STL files of the different methods were superimposed and analyzed with control software (Geomagic Control X, 3D systems) to determine the mean deviation between scans.
Results: Compared to elastomeric impressions, optical impressions showed a significantly improved mean precision. TRIOS3 and CS3600 showed a significantly improved mean trueness compared to that of closed tray, CEREC Omnicam and TrueDefinition. All methods showed a certain degree of implant rotation over their axes, which was significantly higher in the closed tray and the open tray nonsplinted techniques.
Conclusions: Optical impressions, taken under these in vitro conditions, showed improved accuracy compared with that of elastomeric impressions.
Competing Interests: The authors have declared that no competing interests exist.
- References:
J Prosthodont. 2017 Jan;26(1):34-41. (PMID: 26466158)
Eur J Orthod. 2016 Aug;38(4):422-8. (PMID: 26487391)
J Prosthodont. 2018 Jan;27(1):35-41. (PMID: 27483210)
J Prosthodont. 2019 Apr;28(4):e902-e908. (PMID: 29423969)
Implant Dent. 2001;10(2):85-92. (PMID: 11450418)
J Prosthet Dent. 2015 Sep;114(3):403-6.e1. (PMID: 26047800)
Int J Comput Dent. 2015;18(2):101-29. (PMID: 26110925)
J Prosthet Dent. 1996 Mar;75(3):314-25. (PMID: 8648581)
J Prosthet Dent. 2018 Apr;119(4):574-579. (PMID: 28927923)
Int J Prosthodont. 2018 Mar/Apr;31(2):107-113. (PMID: 29518805)
BMC Oral Health. 2014 Jan 30;14:10. (PMID: 24479892)
BMC Oral Health. 2019 Jun 6;19(1):101. (PMID: 31170969)
Int J Oral Maxillofac Implants. 2014;29 Suppl:117-36. (PMID: 24660194)
J Prosthet Dent. 2012 Sep;108(3):165-72. (PMID: 22944312)
J Clin Exp Dent. 2019 Aug 1;11(8):e707-e712. (PMID: 31598199)
Int J Oral Maxillofac Implants. 2017 Feb 23;32(2):313–321. (PMID: 28231346)
Clin Oral Investig. 2018 Apr;22(3):1253-1262. (PMID: 28965251)
Int J Prosthodont. 2002 Jan-Feb;15(1):38-42. (PMID: 11887597)
Quintessence Int. 2007 Jan;38(1):67-73. (PMID: 17216911)
Int J Prosthodont. 2012 Jan-Feb;25(1):44-7. (PMID: 22259795)
Clin Implant Dent Relat Res. 2015 Oct;17 Suppl 2:e751-64. (PMID: 25828851)
J Am Dent Assoc. 2014 Jun;145(6):542-51. (PMID: 24878708)
J Clin Med Res. 2009 Jun;1(2):81-9. (PMID: 22505972)
Int J Prosthodont. 2016 May-Jun;29(3):277-83. (PMID: 27148990)
J Contemp Dent Pract. 2018 Aug 1;19(8):974-981. (PMID: 30150500)
Clin Oral Investig. 2012 Aug;16(4):1137-42. (PMID: 22009182)
Ann Acad Med Singapore. 1995 Jan;24(1):138-57. (PMID: 7605083)
Int J Implant Dent. 2019 Feb 19;5(1):4. (PMID: 30778790)
Clin Oral Implants Res. 2014 Oct;25(10):1113-8. (PMID: 23941118)
J Prosthet Dent. 2015 Aug;114(2):185-92.e1. (PMID: 25935089)
J Clin Exp Dent. 2018 Mar 1;10(3):e252-e263. (PMID: 29721227)
Swed Dent J Suppl. 1985;28:63-9. (PMID: 3904064)
Int J Prosthodont. 2019 Jan/Feb;32(1):66-67. (PMID: 30677114)
Int J Prosthodont. 1995 Nov-Dec;8(6):511-6. (PMID: 8595110)
Eur J Dent Educ. 2017 Aug;21(3):200-205. (PMID: 26960967)
Int J Oral Maxillofac Implants. 2014 Jul-Aug;29(4):869-80. (PMID: 25032767)
Int J Oral Maxillofac Implants. 1997 Jul-Aug;12(4):527-40. (PMID: 9274082)
J Prosthet Dent. 2013 Feb;109(2):121-8. (PMID: 23395338)
Quintessence Int. 2015 Jan;46(1):9-17. (PMID: 25019118)
Int J Dent. 2017;2017:6306530. (PMID: 28348595)
Int J Oral Maxillofac Implants. 2018 Dec 5;34(2):366–380. (PMID: 30521661)
Int J Oral Maxillofac Implants. 2014 Jul-Aug;29(4):836-45. (PMID: 25032763)
J Prosthet Dent. 2017 Apr;117(4):507-512. (PMID: 27881327)
Int J Oral Maxillofac Implants. 1991 Fall;6(3):270-6. (PMID: 1813395)
J Prosthodont. 2017 Dec;26(8):650-655. (PMID: 26934046)
- Accession Number:
0 (Dental Implants)
- Publication Date:
Date Created: 20200228 Date Completed: 20200424 Latest Revision: 20211204
- Publication Date:
20231215
- Accession Number:
PMC7046187
- Accession Number:
10.1371/journal.pone.0228266
- Accession Number:
32106275
No Comments.