Item request has been placed!
×
Item request cannot be made.
×
Processing Request
Plug the needle hub during subcision for a bloodless field.
Item request has been placed!
×
Item request cannot be made.
×
Processing Request
- Additional Information
- Source:
Publisher: Blackwell Science Country of Publication: England NLM ID: 101130964 Publication Model: Print-Electronic Cited Medium: Internet ISSN: 1473-2165 (Electronic) Linking ISSN: 14732130 NLM ISO Abbreviation: J Cosmet Dermatol Subsets: MEDLINE
- Publication Information:
Original Publication: Oxford, UK : Blackwell Science, c2002-
- Subject Terms:
- Abstract:
Background: Subcision is a simple such procedure with considerable efficacy especially in the management of the rolling type of atrophic post-acne scars. Since its introduction in 1995, the technique has undergone several modifications to enhance its results as well as to improve the ergonomics. However, 'gushing' of blood through the hub of the needle smears the surgeon's gloves and the treatment field, which is not desirable both aesthetically and hygienically.
Aim: To describe a simple technique to avoid blood spillage to the treatment field while doing subcision.
Method: While doing subcision, the open hub of the needle used was plugged with a button of sterile cotton and cyanoacrylate glue. The new technique was demonstrated on a patient with atrophic post-acne scars.
Results: There was no blood spillage through the hub of the needle.
Conclusion: This simple modification of subcision helps to attain a bloodless treatment area which also has an added advantage of better assessment of the targeted endpoints at the treatment site.
(© 2019 Wiley Periodicals, Inc.)
- References:
Orentreich DS, Orentreich N. Subcutaneous incisionless (subcision) surgery for the correction of depressed scars and wrinkles. Dermatol Surg. 1995;21:543-549.
Fabbrocini G, Annunziata MC, D'Arco V, et al. Acne scars: pathogenesis, classification and treatment. Dermatol Res Pract. 2010;2010:893080.
Balighi K, Robati RM, Moslehi H, Robati AM. Subcision in acne scar with and without subdermal implant: a clinical trial. J Eur Acad Dermatol Venereol. 2008;22:707-711.
Chandrashekar B, Nandini A. Acne scar subcision. J Cutan Aesthet Surg. 2010;3:125-126.
AlGhamdi KM. A better way to hold a Nokor needle during subcision. Dermatol Surg. 2008;34:378-379.
Al-Khenaizan S. Nokor needle marking: a simple method to maintain orientation during subcision. J Drugs Dermatol. 2007;6:343-344.
Khunger N, Khunger M. Subcision for depressed facial scars made easy using a simple modification. Dermatol Surg. 2011;37:514-517.
- Contributed Indexing:
Keywords: bloodless field; cotton; cutaneous atrophic scars; cyanoacrylate glue; subcision
- Publication Date:
Date Created: 20190831 Date Completed: 20210208 Latest Revision: 20210208
- Publication Date:
20240829
- Accession Number:
10.1111/jocd.13117
- Accession Number:
31468651
No Comments.