Item request has been placed!
×
Item request cannot be made.
×
Processing Request
[Study on fatigue and fracture resistance of metal ceramic crowns with CAD/CAM-fabricated titanium copings].
Item request has been placed!
×
Item request cannot be made.
×
Processing Request
- Author(s): Lian SF;Lian SF; Lin CK; Tsai KT; Chang YH
- Source:
Shanghai kou qiang yi xue = Shanghai journal of stomatology [Shanghai Kou Qiang Yi Xue] 2019 Aprial; Vol. 28 (2), pp. 118-122.
- Publication Type:
Journal Article
- Language:
Chinese
- Additional Information
- Source:
Publisher: School of Stomatology, Shanghai Jiao Tong University Country of Publication: China NLM ID: 101090220 Publication Model: Print Cited Medium: Print ISSN: 1006-7248 (Print) Linking ISSN: 10067248 NLM ISO Abbreviation: Shanghai Kou Qiang Yi Xue Subsets: MEDLINE
- Publication Information:
Publication: Shanghai : School of Stomatology, Shanghai Jiao Tong University
Original Publication: Shanghai : Shanghai di 2 yi ke da xue, Shanghai yi xue hui kou qiang xue hui,
- Subject Terms:
- Abstract:
Purpose: To compare the fatigue and fracture resistance of metal ceramic crowns (MCCs) with nickel-chromium and CAD/CAM-fabricated titanium copings.
Methods: Twelve premolar MCCs were fabricated with cast nickel-chromium alloy (Ni group) and CAD/CAM-fabricated titanium (Ti group) copings, respectively. To minimize the differences among specimens, the geometric dimensions of the MCCs were tested with a laboratory scanner and digital measurement software and then adjusted. After cemented to identically milled titanium dies, each specimen was subjected to thermocycling (5-55℃, 5000 cycles) and cyclic loading (75000 cycles) test, followed by a static load-to-fracture test to measure the fracture loads(F). The fractures were characterized using stereomicroscope. SPSS13.0 software package was used for statistical analysis.
Results: The mean fracture loads were (1645±356)N for Ni group and (1555±331)N for Ti group. No significant difference was observed (P=0.525). Most of the fractures were confined to the palatal third. The chief failure mode for all specimens from Ni group and most of the specimens from Ti groups was mixed failure. Adhesive failure was noted in 3 specimens from Ti group.
Conclusions: The fracture resistance of MCCs with CAD/CAM-fabricated titanium copings is similar to that of MCCs with nickel-chromium copings.
- Accession Number:
0 (Metal Ceramic Alloys)
12001-21-7 (Dental Porcelain)
D1JT611TNE (Titanium)
- Publication Date:
Date Created: 20190807 Date Completed: 20191021 Latest Revision: 20191022
- Publication Date:
20240829
- Accession Number:
31384893
No Comments.