Item request has been placed!
×
Item request cannot be made.
×
Processing Request
Study on the relationship between the concentration and type of fungal bio-aerosols at indoor and outdoor air in the Children's Medical Center, Tehran, Iran.
Item request has been placed!
×
Item request cannot be made.
×
Processing Request
- Additional Information
- Source:
Publisher: Springer Country of Publication: Netherlands NLM ID: 8508350 Publication Model: Electronic Cited Medium: Internet ISSN: 1573-2959 (Electronic) Linking ISSN: 01676369 NLM ISO Abbreviation: Environ Monit Assess Subsets: MEDLINE
- Publication Information:
Publication: 1998- : Dordrecht : Springer
Original Publication: Dordrecht, Holland ; Boston : D. Reidel Pub. Co., c1981-
- Subject Terms:
- Abstract:
Fungal bio-aerosols are of concern due to their adverse health effects, especially in indoor environments. The aim of this study was to evaluate the relationship between the concentration and type of fungal bio-aerosols in the indoor and outdoor of Children's Medical Center in Tehran, Iran. In the present descriptive-analytical study, the fungal bio-aerosols' concentrations in both indoor and outdoor of the hospital air were measured. The measurements were carried out by the Anderson method using a Quick Take 30 pump at 28.3 L min -1 and 2.5 min sampling that was placed on a Sabouraud dextrose agar with chloramphenicol. The average concentrations of total fungal bio-aerosols in the hospital indoor and outdoor air were 40.48 and 119.6 CFU/m 3 , respectively. Onco-hematology and bone marrow transplantation wards were the most and least contaminated units, respectively (11.09 CFU/m 3 vs 1.47 CFU/m 3 ). The most common fungi isolated from the indoor environment were Penicillium spp. (45.86%) which was followed by Cladosporium spp. (31.92%), Aspergillus section Nigri (6.26%), sterilized mycelia (5.05%), and Aspergillus section Flavi (2.83%). Cladosporium spp. (61.10 CFU/m 3 ) and Penicillium spp. (18.56 CFU/m 3 ) had the highest mean concentrations in outdoor and indoor air, respectively. The indoor-to-outdoor ratio of fungal aerosols was < 1 at most sampling sites, indicating that the indoor fungal bio-aerosols may have originated from the outdoor environment.
- References:
Ann Occup Hyg. 2003 Apr;47(3):187-200. (PMID: 12639832)
J Med Vet Mycol. 1992;30 Suppl 1:287-305. (PMID: 1474454)
Infect Control Hosp Epidemiol. 2006 Jan;27(1):44-7. (PMID: 16418986)
J Hosp Infect. 2006 Jul;63(3):246-54. (PMID: 16713019)
Sci Total Environ. 2009 Jun 1;407(12):3766-71. (PMID: 19286244)
Environ Monit Assess. 2012 Mar;184(3):1739-51. (PMID: 21611848)
Environ Monit Assess. 2012 Oct;184(10):6395-409. (PMID: 22086266)
Afr Health Sci. 2012 Jun;12(2):217-25. (PMID: 23056031)
J Air Waste Manag Assoc. 2012 Dec;62(12):1380-93. (PMID: 23362757)
Crit Rev Microbiol. 2014 Aug;40(3):248-60. (PMID: 23586944)
Sci Total Environ. 2014 May 1;479-480:109-16. (PMID: 24561289)
BMC Infect Dis. 2014 Nov 15;14:595. (PMID: 25398412)
J Int Med Res. 2015 Jun;43(3):332-40. (PMID: 25762516)
Res Microbiol. 2015 Sep;166(7):557-63. (PMID: 25869221)
Ann Agric Environ Med. 2016 Jun 2;23(2):264-9. (PMID: 27294630)
Huan Jing Ke Xue. 2016 Apr 15;37(4):1256-63. (PMID: 27548944)
Am J Infect Control. 2016 Sep 2;44(9 Suppl):S109-20. (PMID: 27590695)
Environ Monit Assess. 2017 Jan;189(1):31. (PMID: 28012082)
Antimicrob Agents Chemother. 2017 Apr 24;61(5):. (PMID: 28264849)
Sci Rep. 2017 Sep 11;7(1):11171. (PMID: 28894264)
MethodsX. 2018 Dec 01;5:1588-1596. (PMID: 30622921)
J Air Waste Manag Assoc. 1996 Sep;46(9):899-908. (PMID: 8806223)
Occup Environ Med. 1998 Sep;55(9):579-84. (PMID: 9861178)
- Contributed Indexing:
Keywords: Bio-aerosol concentration; Fungi; Hospital indoor air; I/O ratio; Outdoor air
- Accession Number:
0 (Aerosols)
0 (Air Pollutants)
- Publication Date:
Date Created: 20190106 Date Completed: 20190201 Latest Revision: 20200225
- Publication Date:
20221213
- Accession Number:
10.1007/s10661-018-7183-4
- Accession Number:
30610385
No Comments.