Flow-Induced Dispersion Analysis for Probing Anti-dsDNA Antibody Binding Heterogeneity in Systemic Lupus Erythematosus Patients: Toward a New Approach for Diagnosis and Patient Stratification.

Item request has been placed! ×
Item request cannot be made. ×
loading   Processing Request
  • Additional Information
    • Source:
      Publisher: American Chemical Society Country of Publication: United States NLM ID: 0370536 Publication Model: Print-Electronic Cited Medium: Internet ISSN: 1520-6882 (Electronic) Linking ISSN: 00032700 NLM ISO Abbreviation: Anal Chem Subsets: MEDLINE
    • Publication Information:
      Original Publication: Washington, American Chemical Society.
    • Subject Terms:
    • Abstract:
      Detection of immune responses is important in the diagnosis of many diseases. For example, the detection of circulating autoantibodies against double-stranded DNA (dsDNA) is used in the diagnosis of Systemic Lupus Erythematosus (SLE). It is, however, difficult to reach satisfactory sensitivity, specificity, and accuracy with established assays. Also, existing methodologies for quantification of autoantibodies are challenging to transfer to a point-of-care setting. Here we present the use of flow-induced dispersion analysis (FIDA) for rapid (minutes) measurement of autoantibodies against dsDNA. The assay is based on Taylor dispersion analysis (TDA) and is fully automated with the use of standard capillary electrophoresis (CE) based equipment employing fluorescence detection. It is robust toward matrix effects as demonstrated by the direct analysis of samples composed of up to 85% plasma derived from human blood samples, and it allows for flexible exchange of the DNA sequences used to probe for the autoantibodies. Plasma samples from SLE positive patients were analyzed using the new FIDA methodology as well as by standard indirect immunofluorescence and solid-phase immunoassays. Interestingly, the patient antibodies bound DNA sequences with different affinities, suggesting pronounced heterogeneity among autoantibodies produced in SLE. The FIDA based methodology is a new approach for autoantibody detection and holds promise for being used for patient stratification and monitoring of disease activity.
    • Accession Number:
      0 (Antibodies, Antinuclear)
      9007-49-2 (DNA)
    • Publication Date:
      Date Created: 20160830 Date Completed: 20180815 Latest Revision: 20180815
    • Publication Date:
      20240829
    • Accession Number:
      10.1021/acs.analchem.6b01741
    • Accession Number:
      27571264