What radiation dose does the FISH translocation assay measure in cases of incorporated radionuclides for the Southern Urals populations?
Item request has been placed!
×
Item request cannot be made.
×
Processing Request
- Additional Information
- Source:
Publisher: Oxford University Press Country of Publication: England NLM ID: 8109958 Publication Model: Print-Electronic Cited Medium: Internet ISSN: 1742-3406 (Electronic) Linking ISSN: 01448420 NLM ISO Abbreviation: Radiat Prot Dosimetry Subsets: MEDLINE
- Publication Information:
Publication: 2004- : Oxford, UK : Oxford University Press
Original Publication: Ashford, Kent : Nuclear Technology Pub., c1981-
- Subject Terms:
- Abstract:
The fluorescence in situ hybridisation (FISH) technique is now well established for retrospective dosimetry in cases of external radiation exposure that occurred many years ago. However, the question remains as to whether FISH provides valid estimates of cumulative red bone marrow radiation doses in cases of incorporation of radionuclides or combined external and internal exposures. This question has arisen in connection with the interpretation of results of dose assessments for epidemiological studies of plutonium workers at the Russian Mayak plant and of members of the public exposed to strontium radioisotopes and external radiation as a result of discharges from Mayak to the Techa River. Exposures to penetrating external radiation result in fairly uniform irradiation of body tissues, and hence similar doses to all tissues, for which FISH dosimetry can provide a reliable measure of this whole body dose. However, intakes of radionuclides into the body by inhalation or ingestion may result in retention in specific organs and tissues, so that the distribution of dose is highly heterogeneous. For radionuclides emitting short-range radiations (e.g. alpha particles), this heterogeneity can apply to dose delivery within tissues and between cells within tissues. In this paper, an attempt is made to address the question of what FISH measures in such circumstances by considering evidence regarding the origin and lifetime dynamics of lymphocyte subsets in the human body in relation to the localised delivery of dose from the internal emitters (90)Sr and (239)Pu, which are of particular interest for the Southern Urals Mayak and Techa River populations, and for which most evidence is available in these populations. It is concluded that the FISH translocation assay can be usefully applied for detecting internal and combined external gamma and internal doses from internally deposited (90)Sr, albeit with fairly large uncertainties. The same may be true of (239)Pu, as well as other radionuclides, although much work remains to be done to establish dose-response relationships.
(© Crown copyright 2014.)
- Accession Number:
0 (Strontium Radioisotopes)
53023GN24M (Plutonium)
- Publication Date:
Date Created: 20140417 Date Completed: 20150310 Latest Revision: 20140624
- Publication Date:
20240829
- Accession Number:
10.1093/rpd/ncu118
- Accession Number:
24736296
No Comments.