Item request has been placed!
×
Item request cannot be made.
×
Processing Request
Initial United States experience with the Paracor HeartNet ⁎ [⁎] Paracor Medical, Inc, Sunnyvale, Calif. myocardial constraint device for heart failure.
Item request has been placed!
×
Item request cannot be made.
×
Processing Request
- Author(s): Klodell, Charles T.; McGiffin, David C.; Rayburn, Barry K.; Sun, Benjamin; Abraham, William T.; Conte, John V.; Russell, Stuart D.; Pae, Walter E.; Boehmer, John P.; Aranda, Juan M.
- Source:
Journal of Thoracic & Cardiovascular Surgery; Jan2007, Vol. 133 Issue 1, p204-209, 6p
- Subject Terms:
- Additional Information
- Subject Terms:
- Subject Terms:
- Abstract:
Objective: This study was undertaken to review the initial results and surgical safety data for the US Food and Drug Administration safety and feasibility trial of the Paracor HeartNet (Paracor Medical, Inc, Sunnyvale, Calif.) myocardial constraint device. Methods: Patients with New York Heart Association functional class II or III heart failure underwent device implantation (n = 21) through a left minithoracotomy. Results: The average age was 53 years (31–72 years). There were 18 men and 3 women, and 17 patients had nonischemic etiology of heart failure. Mean heart failure duration was 8.3 years (1.4-18.8 years). Average ejection fraction was 22% (11%-33%), with an average left ventricular end-diastolic dimension of 74 mm (55-94 mm). Previous medical therapy included angiotensin-converting enzyme inhibitors, β-blockers, diuretics, digoxin, and aldosterone receptor blockers. At implantation, 17 patients had implantable electronic devices: 1 biventricular pacemaker, 11 biventricular pacemakers with cardioverter-defibrillators, and 5 implantable cardioverter-defibrillators. Patient comorbidities included hypertension in 10 cases, diabetes mellitus in 8, myocardial infarction in 1, and ventricular tachycardia in 8. Mean operative time was 68 minutes (42–102 minutes), and implantation time averaged 15 minutes (5–51 minutes). The average time to ambulation was 1.6 days (1–4 days). The intensive care unit stay averaged 3.3 days (1–16 days), and hospital stay averaged 6.3 days (4–16 days). Atrial fibrillation occurred in 2 patients, and there were 2 in-hospital deaths. Conclusions: The Paracor device can be implanted in patients with heart failure and reduced left ventricular function with a high degree of success. Significant surgical complications were infrequent. The initial US experience supports the conduct of a randomized, controlled, pivotal trial. [Copyright &y& Elsevier]
- Abstract:
Copyright of Journal of Thoracic & Cardiovascular Surgery is the property of Elsevier B.V. and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
No Comments.