Item request has been placed!
×
Item request cannot be made.
×
Processing Request
The value of low-dose prospective ECG-gated dual-source CT angiography in the diagnosis of coarctation of the aorta in infants and children.
Item request has been placed!
×
Item request cannot be made.
×
Processing Request
- Author(s): Nie P;Nie P; Wang X; Cheng Z; Duan Y; Ji X; Chen J; Zhang H
- Source:
Clinical radiology [Clin Radiol] 2012 Aug; Vol. 67 (8), pp. 738-45. Date of Electronic Publication: 2012 Feb 14.
- Publication Type:
Comparative Study; Journal Article
- Language:
English
- Additional Information
- Source:
Publisher: Blackwell Scientific Publications Ltd Country of Publication: England NLM ID: 1306016 Publication Model: Print-Electronic Cited Medium: Internet ISSN: 1365-229X (Electronic) Linking ISSN: 00099260 NLM ISO Abbreviation: Clin Radiol Subsets: MEDLINE
- Publication Information:
Publication: Oxford : Blackwell Scientific Publications Ltd
Original Publication: Edinburgh, Livingstone.
- Subject Terms:
- Abstract:
Aim: To investigate the value of prospective electrocardiogram (ECG)-gated dual-source computed tomography (DSCT) in the diagnosis of coarctation of the aorta (CoA).
Materials and Methods: Seventeen patients clinically suspected of having CoA underwent prospective ECG-gated DSCT angiography and transthoracic echocardiography (TTE). Surgery was performed in all patients. The diagnostic accuracy of DSCT angiography and TTE was compared with the surgical findings as the reference standard. Image quality was evaluated using a five-point scale. Effective radiation dose was calculated from the dose-length product (DLP).
Results: CoA was diagnosed in 17 patients by DSCT angiography and in 16 patients by TTE. A total of 46 separate cardiovascular abnormalities were confirmed by surgical findings. The diagnostic accuracy of DSCT angiography and TTE was 96.32% and 97.06%, respectively. There was no significant difference in the diagnostic accuracy between DSCT angiography and TTE (χ(2) = 0, p > 0.05). The mean score of image quality was 4.2 ± 0.8. The mean effective dose was 0.69 ± 0.09 mSv.
Conclusion: Prospective ECG-gated DSCT with a low radiation dose is a valuable technique in the diagnosis of CoA in infants and children.
(Copyright © 2012 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.)
- Accession Number:
0 (Contrast Media)
- Publication Date:
Date Created: 20120217 Date Completed: 20120914 Latest Revision: 20161125
- Publication Date:
20231215
- Accession Number:
10.1016/j.crad.2011.12.007
- Accession Number:
22336668
No Comments.