Development of high-performance liquid chromatography and nonaqueous capillary electrophoresis methods for the separation of calixarene derivatives

Item request has been placed! ×
Item request cannot be made. ×
loading   Processing Request
  • Additional Information
    • Abstract:
      Abstract: In the present work, the separations of calixarene derivatives have been investigated using both high-performance liquid chromatography (HPLC) and nonaqueous capillary electrophoresis (NACE) techniques. HPLC-1 method with LC-318 (pore size=300Å) column and MeCN mobile phase was optimized for the separation of calixarenes. At the flow-rate of 1ml/min p-nitrocalix[6]arene, calix[4]arene and calix[6]arene could be well baseline and symmetrically separated within 5min. For the separation of p-tert-butylcalix[n]arenes (n =4, 6, 8), HPLC-2 and NACE methods have been optimized. The optimal conditions in HPLC-2 method included NH2 column and MeCN mobile phase, and p-tert-butylcalix[n]arenes (n =4, 6, 8) were baseline separated within 10min at 0.8min/min. The optimal conditions for NACE method employed MeCN–H2O (8:2, v/v) as the nonaqueous medium and 120mM Tris/HCl (pH 9.0) as the buffer, and p-tert-butylcalix[n]arenes (n =4, 6, 8) were successfully baseline resolved within 16min. With the detection at 280nm, the calibration lines were linear in the ranges of 1–200μg/ml for calixarene derivatives by HPLC-1 and HPLC-2 methods, and of 2.5–200μg/ml for p-tert-butylcalix[n]arenes (n =4, 6, 8) by NACE method, respectively. The detection limits (S/N=3) and recoveries ranged from 0.5 to 1.4μg/ml and from 98.1 to 102.4% by both HPLC-1 and HPLC-2 methods, and from 1.3 to 2.0μg/ml and from 97.9 to 105.1% by NACE method, respectively. The intra-day reproducibility of the methods was determined with satisfactory results. The proposed HPLC and NACE methods were accurate and reproducible, and could be utilized to separate and determine calixarene derivatives. [Copyright &y& Elsevier]
    • Abstract:
      Copyright of Analytica Chimica Acta is the property of Elsevier B.V. and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)