Rotational thrombelastometry for the bedside monitoring of recombinant hirudin.

Item request has been placed! ×
Item request cannot be made. ×
loading   Processing Request
  • Author(s): Sucker C;Sucker C; Zotz RB; Görlinger K; Hartmann M
  • Source:
    Acta anaesthesiologica Scandinavica [Acta Anaesthesiol Scand] 2008 Mar; Vol. 52 (3), pp. 358-62. Date of Electronic Publication: 2008 Jan 16.
  • Publication Type:
    Evaluation Study; Journal Article
  • Language:
    English
  • Additional Information
    • Source:
      Publisher: Wiley-Blackwell Country of Publication: England NLM ID: 0370270 Publication Model: Print-Electronic Cited Medium: Internet ISSN: 1399-6576 (Electronic) Linking ISSN: 00015172 NLM ISO Abbreviation: Acta Anaesthesiol Scand Subsets: MEDLINE
    • Publication Information:
      Publication: Oxford, UK : Wiley-Blackwell
      Original Publication: Aarhus, Denmark : Universitetsforlaget, 1957-
    • Subject Terms:
    • Abstract:
      Background: Recombinant hirudin is used as an alternative anticoagulant, particularly in patients with heparin-induced thrombocytopenia type II. However, bedside monitoring for hirudin is not available. The present study aims to evaluate rotational thrombelastometry regarding its suitability to detect the effects of recombinant hirudin on whole blood coagulation. Hirudin was added to whole blood samples from healthy donors (n=5) and thrombelastometry variables resulting from activation of samples with tissue factor, ellagic acid, and ecarin were determined.
      Methods: Hirudin (0.1-10 microg/ml) was added to citrated blood. Thereafter, rotational thrombelastometry was performed by initiating coagulation via recalcification and addition of tissue factor, ellagic acid, and ecarin, respectively, using the commercially available assays.
      Results: In the absence of hirudin, clotting times (CT) induced by ellagic acid, tissue factor, and ecarin, respectively, were 141.7+/-18.0, 54.0+/-7.6, and 64.5+/-4.1 s. Increasing concentrations of hirudin led to dose-dependent prolongation of the clotting time with the three activators. All assays were capable to detect hirudin concentrations in the range of 0.5-5 microg/ml. At a final hirudin concentration of 1 microg/ml, clotting time increased to 268.0+/-25.1, 84.0+/-9.3, and 107.5+/-9.9 s, respectively, with the above-mentioned activators. The other thrombelastographic variables, including clot formation time, angle alpha, and maximum clot firmness, were not altered by hirudin at concentrations up to 5 microg/ml.
      Conclusions: Our study demonstrates the suitability of rotational thrombelastometry to detect anticoagulant effects of recombinant hirudin.
    • Accession Number:
      0 (Anticoagulants)
      0 (Fibrinolytic Agents)
      0 (Hirudins)
      0 (Recombinant Proteins)
      9005-49-6 (Heparin)
    • Publication Date:
      Date Created: 20080122 Date Completed: 20080408 Latest Revision: 20191210
    • Publication Date:
      20240829
    • Accession Number:
      10.1111/j.1399-6576.2007.01550.x
    • Accession Number:
      18205897