    • Abstract:
      Background. Dislocations of the acromial end of the clavicle are quite common traumatic injuries of the locomotor apparatus and, according to various authors, account for 3 to 26.1 % of dislocations of other locations and about 10 % in the structure of acute injuries of the shoulder girdle, ranking third after dislocated shoulders and forearms. They occur mainly in young men of the most working age, which determines the social significance of this injury. Stabilization of the acromial end of the clavicle, as a rule, was ensured by fixation according to Weber and the use of a hook plate. The purpose of the study: to determine the shortcomings and strength characteristics of the fastening elements in the fixation of the acromial end of the clavicle according to Weber. Materials and methods. From 2015 to 2020, a retrospective analysis was performed of treatment outcomes in 57 patients who underwent surgery for dislocation of the acromial end of the clavicle and Weber fixation. Calculations of the strength of fixation of the acromial end of the clavicle with a cerclage wire and spikes in case of its dislocation were carried out in the biomechanics laboratory of the State Institution “Sytenko Institute of Spine and Joint Pathology of the National Academy of Medical Sciences of Ukraine”. Results. According to the results of clinical studies, a violation of the integrity of the wire and spikes was observed in 10.5 % of cases, destruction of the acromion process and acromial end of the clavicle — in 19.3 %, migration of the spikes — in 12.3 %. Results of the experimental study show that these shortcomings are clearly correlated with the mechanical properties of the wire and spikes. Conclusions. The factors for unsatisfactory results of surgical treatment for dislocations of the acromial end of the clavicle when using Weber’s method are the violation of the integrity of the wire and spikes, the destruction of the acromion process and the acromial end of the clavicle, the migration of the spikes, which are caused by the mechanical properties of these structures. [ABSTRACT FROM AUTHOR]
    • Abstract:
      Copyright of Travma is the property of Zaslavsky O.Yu and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)