[A simultaneous detection of Chlamydia pneumoniae and Chlamydia trachomatis DNA by real-time PCR].

Item request has been placed! ×
Item request cannot be made. ×
loading   Processing Request
  • Author(s): Roubalová K;Roubalová K
  • Source:
    Epidemiologie, mikrobiologie, imunologie : casopis Spolecnosti pro epidemiologii a mikrobiologii Ceske lekarske spolecnosti J.E. Purkyne [Epidemiol Mikrobiol Imunol] 2007 Nov; Vol. 56 (4), pp. 166-73.
  • Publication Type:
    English Abstract; Journal Article
  • Language:
    Czech
  • Additional Information
    • Transliterated Title:
      Soucasný průkaz DNA Chlamydia pneumoniae a Chlamydia trachomatis pomoci real-time PCR.
    • Source:
      Publisher: Ceská lékarská spolecnost J.E. Purkyne Country of Publication: Czech Republic NLM ID: 9431736 Publication Model: Print Cited Medium: Print ISSN: 1210-7913 (Print) Linking ISSN: 12107913 NLM ISO Abbreviation: Epidemiol Mikrobiol Imunol Subsets: MEDLINE
    • Publication Information:
      Original Publication: Praha : Ceská lékarská spolecnost J.E. Purkyne, c1994-
    • Subject Terms:
    • Abstract:
      Study Objective: Design and validation of a real-time PCR assay for quantitative detection of C. pneumoniae and C. trachomatis in clinical specimens.
      Material and Methods: A part of the 16S RNA gene was selected as the target sequence for amplification. The reaction product was cloned in the bacterial plasmid and a recombinant calibrator and a combined internal standard were prepared, usable in three different PCR assays. Archived DNA isolates from various clinical specimens, DNA isolates from other infectious agents and control samples for DNA detection, CT (QCMD) and CPN (Instand), were used for validation.
      Results: Reaction specificity and reproducibility were tested. The analytical sensitivity was set to 5-10 copies of the bacterial genome/reaction. As many as 105 DNA isolates from various types of clinical specimens (swabs, urine, peripheral blood and BAL fluid) were tested by real-time PCR and conventional PCR assays. The specimens that had not yielded concordant results were characterized by a third independent amplification test. The sensitivity and specificity of real-time PCR were 89% and 100%, respectively. The assay is suitable for both screening and diagnosis of Chlamydia.
    • Accession Number:
      0 (DNA, Bacterial)
    • Publication Date:
      Date Created: 20071211 Date Completed: 20080205 Latest Revision: 20071210
    • Publication Date:
      20240829
    • Accession Number:
      18064798