Improving Breath Detection From Pulsed-Flow Oxygen Sources Using a New Nasal Interface.

Item request has been placed! ×
Item request cannot be made. ×
loading   Processing Request
  • Additional Information
    • Abstract:
      BACKGROUND: Patients with COPD and other lung diseases are treated with long-term oxygen therapy (LTOT). Portable oxygen sources are required to administer LTOT while maintaining patient autonomy. Existing portable oxygen equipment has limitations that can hinder patient mobility. A novel nasal interface is presented in this study, aiming to enhance breath detection and triggering efficiency of portable pulsed-flow oxygen devices, thereby improving patient mobility and independence. METHOD: To examine the effectiveness of the new interface, 8 respiratory therapists participated in trials using different oxygen sources (tank with oxygen-conserving device, SimplyGo Mini portable oxygen concentrator [POC], and OxyGo NEXT POC) and breathing types (nasal and oral) while using either the new nasal interface or a standard cannula. Each trial was video recorded so participant breaths could be retroactively matched with a pulse/no-pulse response, and triggering success rates were calculated by dividing the number of oxygen pulses by the number of breaths in each trial. After each trial, volunteers were asked to rate their perceived breathing resistance. RESULTS: Nasal breathing consistently resulted in higher triggering success rates compared to oral breathing for pulsed-flow oxygen devices. POCs exhibited higher triggering success rates than did the oxygen tanks with conserving device. However, there were no significant differences in triggering success rates between the two POC models. The new nasal interface demonstrated improved triggering success rates compared to the standard cannula. Whereas the new nasal inter- face was associated with a slight increase in perceived breathing resistance during nasal breathing trials, participants reported manageable resistance levels when using the interface. CONCLUSIONS: This study demonstrates that the new nasal interface can improve triggering success rates of pulsed-flow oxygen devices during both nasal and oral breathing scenarios. Further research involving patient trials is recommended to understand the clinical implications of improved pulse triggering. [ABSTRACT FROM AUTHOR]
    • Abstract:
      Copyright of Respiratory Care is the property of American Association for Respiratory Care and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)