Item request has been placed!
×
Item request cannot be made.
×
Processing Request
Angiographic measurement of the superficial temporal artery for potential use in cerebral bypass surgery: a combined radiological and cadaveric study.
Item request has been placed!
×
Item request cannot be made.
×
Processing Request
- Additional Information
- Abstract:
Purpose: This study aims to investigate the microsurgical anatomy of the superficial temporal artery (STA), explore the relationship between STA length and lumen diameter, and develop a reliable radiologic method for selecting STA segments for bypass surgery. Methods: This study used 10 cadaveric dissections (20 STAs, both sides) and 20 retrospective radiological examinations (40 STAs, both sides), employing curved multiplanar reformation and flow color lookup table (CLUT) DICOM processing. Measurements included vessel lumen diameters and luminal cross-sectional thicknesses 3 mm proximal to the STA bifurcation, 3 mm distal to the frontal branch, 5 cm distal to the frontal branch, 3 mm distal to the parietal branch, and 5 cm distal to the parietal branch. The distance between the STA bifurcation and the superior zygomatic border (SZB) was also measured. In our analysis, descriptive statistics encompassed mean, standard deviation (SD), standard error, minimum and maximum values, and distributions. Comparative statistics were performed using Student's t-test, with statistical significance set at p < 0.05. Results: There were no statistically significant differences between STA measurements of bifurcation distances (p = 0.88) and lumen diameters (p = 0.46) between cadavers and radiological measures. However, lumen thicknesses were larger in frontal branches than parietal branches at the seventh and eighth centimeter (p = 0.012, p = 0.039). Branches became thinner distally from the zygoma in both cadavers and radiological image measurements. Conclusion: The CLUT DICOM processing radiological measures provided the high-precision required to enable pre-surgical vessel selection for extracranial-intracranial bypass. The results show that STA vessel luminal diameters are sufficient (> 1 mm) for bypass surgery in the first 9 cm but gradually decrease after that. Also shown is that the choice of frontal versus parietal branches depends on individual anatomical features; therefore, careful preoperative radiological examination is critical. [ABSTRACT FROM AUTHOR]
- Abstract:
Copyright of Surgical & Radiologic Anatomy is the property of Springer Nature and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
No Comments.