An innovative asymmetrical CPC with integrated PCM as an in-line water heater.
Item request has been placed!
×
Item request cannot be made.
×
Processing Request
- Additional Information
- Subject Terms:
- Abstract:
• An innovative in-line water heater solar thermal collector is proposed. • PCM function was validated through experimental results from literature (<5% deviations). • The collector was optically optimized and exceeded another one from literature by up to 30%. • The implementation of fins enhances significantly the performance of the collector. • The 8x8 plus geometry ensures 96% more useful output (2.78 kWh) than the no-fin one. In the present work, an innovative asymmetrical evacuated tube compound parabolic collector (CPC) with integrated Phase Change Material (PCM) is proposed as an in-line water heater. This solar collector was examined numerically as regards its thermal and optical operation. The optical efficiency was firstly optimized by modifying two independent design variables of the reflector. Then the optical performance was calculated for the finally selected geometry, considering 15 different transversal incident angles. As regards the thermal operation of the collector, the charging and discharging of PCM were investigated in detail. Four different internal fin arrangements were compared to the no-fin case and each other and the optimum one was revealed. The simulations were conducted for the city of Athens in Greece considering the typical clear day in July. It was considered that there is a charging period of five hours from 09:00 to 14:00 (solar time) and then a discharging one with a duration of one hour. For the thermal optimization, a volumetric flow rate of 4 L/min was selected during the discharging phase. The water temperature from the grid was considered to have a temperature of around 20 °C. The main parameters which were evaluated during charging and discharging were the useful power output, the outlet water temperature and the mean PCM temperature. For validation purposes, experimental results from a previous study were used. In the previous study, a PCM heat exchanger with water as the working fluid was examined experimentally. The same heat exchanger was designed in the present study for comparing the results. It was found that the present numerical results are very close to the experimental of the previous study with a mean deviation of 1.60 % and a maximum of 4.24 %. The design and the numerical simulations were conducted with SolidWorks Flow Simulation software. The final results show that the best design leads to 96 % higher daily useful heat production compared to the baseline case without fins. [ABSTRACT FROM AUTHOR]
- Abstract:
Copyright of Solar Energy is the property of Pergamon Press - An Imprint of Elsevier Science and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
No Comments.