Performance Assessment of a Novel Multianalyte Methodology for Celiac Disease Biomarker Detection and Evaluation of the Serology-Alone Criteria for Biopsy-Free Diagnosis.

Item request has been placed! ×
Item request cannot be made. ×
loading   Processing Request
  • Additional Information
    • Subject Terms:
    • Subject Terms:
    • Abstract:
      Context.-- Serology plays a vital role in celiac disease (CD) diagnosis, and the latest European guidelines advocate for biopsy-free diagnoses in patients with ≥10x the upper limit of normal (ULN) of anti-tissue transglutaminase (tTG) immunoglobulin A (IgA) antibodies. Objective.-- To assess performance characteristics of a novel automated particle-based multianalyte technology (Aptiva) for anti-tTG and anti-deamidated gliadin peptide (DGP) antibody detection as compared to the traditional enzyme-linked immunosorbent assay (QUANTA Lite). Performance characteristics of the ≥10x ULN anti-tTG IgA criteria for serologic diagnosis of CD were also evaluated. Design.-- Sera samples from 703 patients were tested for anti-tTG IgA, anti-tTG immunoglobulin G (IgG), anti-DGP IgA, and anti-DGP IgG antibodies on both platforms. In total, 127 patients had medical information and were classified as CD-positive (n = 58) and CD-negative (n = 69) based on biopsy results. Clinical performance characteristics were evaluated. Results.-- Anti-tTG IgA detection showed equal clinical sensitivity and specificity of 91% sensitivity and 99% specificity on both platforms. Anti-tTG IgG resulted in moderate sensitivity of 69% and 72%, but high specificity of 100% and 94% on Aptiva and QUANTA Lite, respectively. Anti-DGP IgG displayed comparable sensitivity of 90% and 81%, and a specificity of 94% and 99%, on Aptiva and QUANTA Lite, respectively. Anti-DGP IgA demonstrated greater sensitivity on QUANTA Lite (83%) than Aptiva (69%) and similar specificities of 97% and 98% on QUANTA Lite and Aptiva, respectively. At ≥10x ULN levels for anti-tTG IgA, Aptiva displayed a sensitivity of 72% and a specificity of 100%, and QUANTA Lite showed a sensitivity of 69% and a specificity of 100%. Conclusions.-- Aptiva is a reliable method to measure CD biomarkers with reduced hands-on necessity and high-throughput capabilities. This study supports the use of a ≥10x ULN anti-tTG IgA biopsy-free approach for serologic diagnosis of CD. [ABSTRACT FROM AUTHOR]
    • Abstract:
      Copyright of Archives of Pathology & Laboratory Medicine is the property of College of American Pathologists and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)