Sustainable and Rapid Determination of Two Halogenated Pesticides in a Commercial Formulation by Solid Phase Microextraction and Liquid Phase Chemical Ionization Mass Spectrometry.
Item request has been placed!
×
Item request cannot be made.
×
Processing Request
- Author(s): Marittimo, Nicole; Grasselli, Genny; Arigò, Adriana; Famiglini, Giorgio; Palma, Pierangela; Saeed, Mansoor; Perry, Simon; Navarro, Pablo; Clarke, Phil; Brittin, Mark; Cappiello, Achille
- Source:
Separations (2297-8739); Jun2023, Vol. 10 Issue 6, p325, 13p
- Subject Terms:
- Additional Information
- Abstract:
This work presents a sustainable and rapid method for halogenated pesticide analysis without chromatographic separation. The system is composed of a microfluidic open interface (MOI) for solid-phase microextraction (SPME) liquid phase desorption, connected to a liquid electron ionization mass spectrometry interface (LEI-MS). Either a triple quadrupole mass spectrometer (QQQ-MS/MS, (low-resolution) or a quadrupole-time-of-flight tandem MS (QTOF-MS/MS, high-resolution) were employed, each operating in negative chemical ionization (NCI) conditions. The flow rate used (100 µL/min) to rapidly empty the MOI chamber (approximately 2.5 µL) is reduced to the working flow rate of the LEI interface (500 nL/min) by a passive flow splitter (PFS). NCI is an appropriate ionization technique for electrophilic compounds, increasing specificity and reducing background noise. Two halogenated pesticides, dicamba and tefluthrin, were extracted simultaneously from a commercial formulation matrix (CF) using a C18 fiber by direct immersion (3 min under vortex agitation). Analyte desorption occurred in static conditions inside MOI filled with acidified acetonitrile (ACN) (0.2% phosphoric acid, PA). Extraction and desorption steps were optimized to increase efficiency and accelerate the process. No chromatographic separation was involved; therefore, the system fully exploited MS/MS selectivity and HRMS accuracy demonstrating good linearity, repeatability and limits of detection (LODs) and limits of quantification (LOQs) in the pg/mL range (50 and 500 pg/mL, respectively). Low-resolution experiments showed that matrix effects (ME) did not affect the results. The fast workflow (5 min) makes the system suitable for high-throughput analysis observing the principles of green analytical chemistry (GAC). [ABSTRACT FROM AUTHOR]
- Abstract:
Copyright of Separations (2297-8739) is the property of MDPI and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
No Comments.