Toward a robust swallowing detection for an implantable active artificial larynx: a survey.

Item request has been placed! ×
Item request cannot be made. ×
loading   Processing Request
  • Author(s): Mialland, Adrien (AUTHOR); Atallah, Ihab (AUTHOR); Bonvilain, Agnès (AUTHOR)
  • Source:
    Medical & Biological Engineering & Computing. Jun2023, Vol. 61 Issue 6, p1299-1327. 29p. 1 Color Photograph, 1 Black and White Photograph, 3 Diagrams, 3 Graphs.
  • Additional Information
    • Subject Terms:
    • Abstract:
      Total laryngectomy consists in the removal of the larynx and is intended as a curative treatment for laryngeal cancer, but it leaves the patient with no possibility to breathe, talk, and swallow normally anymore. A tracheostomy is created to restore breathing through the throat, but the aero-digestive tracts are permanently separated and the air no longer passes through the nasal tracts, which allowed filtration, warming, humidification, olfaction, and acceleration of the air for better tissue oxygenation. As for phonation restoration, various techniques allow the patient to talk again. The main one consists of a tracheo-esophageal valve prosthesis that makes the air passes from the esophagus to the pharynx, and makes the air vibrate to allow speech through articulation. Finally, swallowing is possible through the original tract as it is now isolated from the trachea. Yet, many methods exist to detect and assess a swallowing, but none is intended as a definitive restoration technique of the natural airway, which would permanently close the tracheostomy and avoid its adverse effects. In addition, these methods are non-invasive and lack detection accuracy. The feasibility of an effective early detection of swallowing would allow to further develop an implantable active artificial larynx and therefore restore the aero-digestive tracts. A previous attempt has been made on an artificial larynx implanted in 2012, but no active detection was included and the system was completely mechanic. This led to residues in the airway because of the imperfect sealing of the mechanism. An active swallowing detection coupled with indwelling measurements would thus likely add a significant reliability on such a system as it would allow to actively close an artificial larynx. So, after a brief explanation of the swallowing mechanism, this survey intends to first provide a detailed consideration of the anatomical region involved in swallowing, with a detection perspective. Second, the swallowing mechanism following total laryngectomy surgery is detailed. Third, the current non-invasive swallowing detection technique and their limitations are discussed. Finally, the previous points are explored with regard to the inherent requirements for the feasibility of an effective swallowing detection for an artificial larynx. [ABSTRACT FROM AUTHOR]
    • Abstract:
      Copyright of Medical & Biological Engineering & Computing is the property of Springer Nature and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)