Item request has been placed!
×
Item request cannot be made.
×
Processing Request
Feasibility of non-invasive neuro-monitoring during extracorporeal membrane oxygenation in children.
Item request has been placed!
×
Item request cannot be made.
×
Processing Request
- Author(s): McDevitt, William M; Farley, Margaret; Martin-Lamb, Darren; Jones, Timothy J; Morris, Kevin P; Seri, Stefano; Scholefield, Barnaby R
- Source:
Perfusion; Apr2023, Vol. 38 Issue 3, p547-556, 10p
- Subject Terms:
- Additional Information
- Abstract:
Introduction: Detection of neurological complications during extracorporeal membrane oxygenation (ECMO) may be enhanced with non-invasive neuro-monitoring. We investigated the feasibility of non-invasive neuro-monitoring in a paediatric intensive care (PIC) setting. Methods: In a single centre, prospective cohort study we assessed feasibility of recruitment, and neuro-monitoring via somatosensory evoked potentials (SSEP), electroencephalography (EEG) and near infrared spectroscopy (NIRS) during venoarterial (VA) ECMO in paediatric patients (0–15 years). Measures were obtained within 24h of cannulation, during an intermediate period, and finally at decannulation or echo stress testing. SSEP/EEG/NIRS measures were correlated with neuro-radiology findings, and clinical outcome assessed via the Pediatric cerebral performance category (PCPC) scale 30 days post ECMO cannulation. Results: We recruited 14/20 (70%) eligible patients (median age: 9 months; IQR:4–54, 57% male) over an 18-month period, resulting in a total of 42 possible SSEP/EEG/NIRS measurements. Of these, 32/42 (76%) were completed. Missed recordings were due to lack of access/consent within 24 h of cannulation (5/42, 12%) or PIC death/discharge (5/42, 12%). In each patient, the majority of SSEP (8/14, 57%), EEG (8/14, 57%) and NIRS (11/14, 79%) test results were within normal limits. All patients with abnormal neuroradiology (4/10, 40%), and 6/7 (86%) with poor outcome (PCPC ≥4) developed indirect SSEP, EEG or NIRS measures of neurological complications prior to decannulation. No study-related adverse events or neuro-monitoring data interpreting issues were experienced. Conclusion: Non-invasive neuro-monitoring (SSEP/EEG/NIRS) during ECMO is feasible and may provide early indication of neurological complications in this high-risk population. [ABSTRACT FROM AUTHOR]
- Abstract:
Copyright of Perfusion is the property of Sage Publications, Ltd. and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
No Comments.