Closed‐loop control of air supply to whole‐room indirect calorimeters to improve accuracy and standardize measurements during 24‐hour dynamic metabolic studies.

Item request has been placed! ×
Item request cannot be made. ×
loading   Processing Request
  • Additional Information
    • Abstract:
      Objective: The aim of this study was to test proportional‐integral‐derivative (PID) control of air inflow rate in a whole‐room indirect calorimeter to improve accuracy in measuring oxygen (O2) consumption (V̇O2) and carbon dioxide (CO2) production (V̇CO2). Methods: A precision gas blender infused nitrogen (N2) and CO2 into the calorimeter over 24 hours based on static and dynamic infusion profiles mimicking V̇O2 and V̇CO2 patterns during resting and non‐resting conditions. Constant (60 L/min) versus time‐variant flow set by a PID controller based on the CO2 concentration was compared based on errors between measured versus expected values for V̇O2,V̇CO2, respiratory exchange ratio, and metabolic rate. Results: Compared with constant inflow, the PID controller allowed both a faster rise time and long‐term maintenance of a stable CO2 concentration inside the calorimeter, resulting in more accurate V̇CO2 estimates (mean hourly error, PID: −0.9%, 60 L/min = −2.3%, p < 0.05) during static infusions. During dynamic infusions mimicking exercise sessions, the PID controller achieved smaller errors for V̇CO2 (mean: −0.6% vs. −2.7%, p = 0.02) and respiratory exchange ratio (mean: 0.5% vs. −3.1%, p = 0.02) compared with constant inflow conditions, with similar V̇O2 (p = 0.97) and metabolic rate (p = 0.76) errors. Conclusions: PID control in a whole‐room indirect calorimeter system leads to more accurate measurements of substrate oxidation during dynamic metabolic studies. [ABSTRACT FROM AUTHOR]
    • Abstract:
      Copyright of Obesity (19307381) is the property of Wiley-Blackwell and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)