Rist Guide Catheter for Endovascular Procedures: Initial Case Series from a Single Center.
Item request has been placed!
×
Item request cannot be made.
×
Processing Request
- Author(s): Waqas, Muhammad1,2 (AUTHOR); Monteiro, Andre1,2 (AUTHOR); Baig, Ammad A1,2 (AUTHOR); Cappuzzo, Justin M1,2 (AUTHOR); Dossani, Rimal H1,2 (AUTHOR); Almayman, Faisal1,2 (AUTHOR); Singh, Trisha2 (AUTHOR); Snyder, Kenneth V1,2,3,4 (AUTHOR); Levy, Elad I1,2,3,4,5 (AUTHOR); Siddiqui, Adnan H1,2,3,4,5 (AUTHOR); Davies, Jason M1,2,3,4,6 (AUTHOR)
- Source:
Interventional Neuroradiology. Feb2023, Vol. 29 Issue 1, p108-113. 6p.
- Subject Terms:
- Additional Information
- Abstract:
Background: The transradial approach (TRA) for endovascular procedures has become a frequent practice in neurointervention. Advantages of the TRA include less access-site complications, early ambulation, and less postprocedural pain. The Rist 079 radial access guide catheter (Medtronic) is the first device designed specifically for neurointerventions performed through the TRA. In this study, we report our initial experience with the Rist catheter in a variety of neurointerventional procedures, aiming to evaluate the performance of this device and discuss its limitations. Methods: A prospectively maintained database was retrospectively searched to identify patients who underwent procedures using the Rist catheter. Information on demographics, procedural details, and complications was recorded. Results: Seventy-eight patients were included in the study, with a mean age of 60.3 years (range, 25–92 years); 45 (57.7%) were men. The interventional or diagnostic procedure was successfully completed in 77 patients (98.7%). The radial artery was the primary access-site choice in 71 patients (91%). The most frequent type of procedures performed were coiling or stent-assisted coiling (16.7%) and angioplasty and stenting (16.7%), followed by middle meningeal artery embolization (14.1%). Crossover to femoral artery access while maintaining use of the Rist was done in 5 cases (6.4%). Reasons for access or procedural failure included anatomical anomaly of the target vessel, unfavorable geometry of the great vessels, and proximal tortuosity of the supra-aortic vessels. Conclusion: We demonstrated a high success rate with use of the Rist catheter system for a variety of procedures. [ABSTRACT FROM AUTHOR]
- Abstract:
Copyright of Interventional Neuroradiology is the property of Sage Publications, Ltd. and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
No Comments.