Item request has been placed!
×
Item request cannot be made.
×
Processing Request
Neuromuscular blockade in mechanically ventilated pneumonia patients with moderate to severe hypoxemia: A multicenter retrospective study.
Item request has been placed!
×
Item request cannot be made.
×
Processing Request
- Additional Information
- Abstract:
Background/Purpose: The benefit of neuromuscular blockades (NMBs) in critically ill patients receiving mechanical ventilation remains uncertain. Therefore, we aimed to investigate whether NMB use is associated with improved survival of mechanically ventilated pneumonia patients with moderate to severe hypoxemia. Methods: This retrospective multicenter study was conducted at five university-affiliated hospitals. Data of pneumonia patients aged 18 years and older who received mechanical ventilation between January 1, 2011, and December 31, 2020, were analyzed. Results: In a total of 1,130 patients, the mean patient age was 73.1 years (SD±12.6), and the overall mortality rate at 30 d was 29.5% (n = 333). NMB users had a higher 30 d mortality rate than NMB nonusers (33.9% vs. 26.8%, P = 0.014). After PS matching, the 30 d mortality rate was not significantly different between NMB users and nonusers (33.4% vs. 27.8%, p = 0.089). However, 90 d mortality rate was significantly increased in NMB users (39.7% vs. 31.9%, p = 0.021). Univariable Cox proportional hazard regression analyses showed that NMB use ≥ 3 d was significant risk factor for the 90 d mortality than those with < 3 d use (90 d mortality HR 1.39 [95% CI: 1.01–1.91], P = 0.045). Conclusions: NMB use was not associated with lower 30 d mortality among mechanically ventilated pneumonia patients with moderate to severe hypoxemia. Rather, NMB users had higher 90 d mortality, furthermore, and NMB use ≥ 3 d was associated with a higher risk of long-term mortality compared to NMB use < 3 d. Therefore, care should be taken to avoid extended use of NMB in critically ill pneumonia patients during mechanical ventilation. [ABSTRACT FROM AUTHOR]
- Abstract:
Copyright of PLoS ONE is the property of Public Library of Science and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
No Comments.