Clinical application of MIIRMR as a salvage method in gadolinium-enhanced MRI after intra-tympanic injection.

Item request has been placed! ×
Item request cannot be made. ×
loading   Processing Request
  • Additional Information
    • Subject Terms:
    • Abstract:
      Three-dimensional fluid-attenuated inversion-recovery (3 D-FLAIR) and real inversion-recovery (3 D-real IR) sequences are used to detect endolymphatic hydrops (EH), but medium inversion-time inversion-recovery imaging with magnitude reconstruction (MIIRMR) may be more sensitive. We investigated the inner-ear visualisation success rate and EH detection rates of 3 D-FLAIR and 3 D-real IR, and whether salvage MIIRMR could improve EH detection. Fifty-one patients (102 ears) with episodic or chronic vestibular syndrome were injected intra-tympanically with 8-fold diluted gadolinium, and 3 D-FLAIR and 3 D-real IR images obtained 24-h post-injection. If 3 D-FLAIR inner-ear visualisation failed, additional MIIRMR was performed. The success and EH detection rate increase by MIIRMR was calculated. The diagnostic performance of combined MIIRMR + 3D-FLAIR + 3D-real IR for Meniere's disease (MD) was evaluated. The success rates of 3 D-FLAIR and 3 D-real IR were 88.90% and 72.55%, respectively. MIIRMR increased the success and EH detection rates by 11.10% and 6.86%, respectively. In MD, MIIRMR increased these rates by 10.53% and 10.53%, respectively. 3 D-FLAIR + 3D-real IR + MIIRMR had 92.11% sensitivity, 79.68% specificity, 72.92% positive-predictive value, and 94.44% negative-predictive value for MD diagnosis. MIIRMR can improve success and EH detection rates when 3 D-FLAIR fails. Combined MIIRMR + 3D-FLAIR + 3D-real IR is more valuable for diagnosing MD than conventional sequences. [ABSTRACT FROM AUTHOR]
    • Abstract:
      背景:三维流体衰减反转恢复 (3D-FLAIR) 和真实反转恢复 (3D-real IR) 序列用于检测内淋巴水肿 (EH), 但具幅度重建的中等反转时间反转恢复成像 (MIIRMR) 可能更敏感。 目的:我们研究了 3D-FLAIR和3 D-real IR 的内耳可视化成功率和 EH 检出率, 探讨了挽救性 MIIRMR 是否可以改善 EH 检测。 材料和方法:51 例(102 只耳)发作性或慢性前庭综合征患者鼓室内注射 8 倍稀释的钆, 并在注射后 24 小时拍得 3D-FLAIR 和 3D-real IR 图像。如果 3D-FLAIR 内耳可视化失败, 则再进行一次 MIIRMR。计算因MIIRMR 而提高的成功率和 EH 检测率。评估了组合的 MIIRMR + 3D-FLAIR + 3D-real IR 对梅尼埃病 (MD) 的诊断性能。 结果:3D-FLAIR和3D-real IR的成功率分别为88.90%和72.55%。 MIIRMR成功率和 EH 检测率分别提高了 11.10% 和 6.86%。对于梅尼埃病, MIIRMR将这些比率分别提高了 10.53% 和 10.53%。对于MD诊断, 3D-FLAIR + 3D-real IR + MIIRMR 具有92.11% 敏感性、79.68% 特异性、72.92% 阳性预测值和 94.44% 阴性预测值价值。 结论与意义:MIIRMR 可提高成功率和 EH 检出率, 而3D-FLAIR 却做不到。组合 MIIRMR + 3D-FLAIR + 3D-real IR 对于诊断 MD 比传统序列更有价值。 [ABSTRACT FROM AUTHOR]
    • Abstract:
      Copyright of Acta Oto-Laryngologica is the property of Taylor & Francis Ltd and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)