OCT-Angiography: Mydriatic phenylephrine and tropicamide do not influence retinal microvasculature in macula and peripapillary region.
Item request has been placed!
×
Item request cannot be made.
×
Processing Request
- Additional Information
- Abstract:
Optical coherence tomography angiography (OCT-A) enables visualization of retinal microcirculation. As a potential influence of mydriatic eye drops on retinal vessel density (VD) was proposed, the purpose of the present study was to investigate an influence of 5% phenylephrine and 0.5% tropicamide on macula and peripapillary VD. 30 eyes of 30 healthy persons were measured by en face OCT-A (Spectralis OCT II, Heidelberg Engineering, Heidelberg). Scans of the macula (12 sectors, region of interest, ROI: 6.10 mm2) and peripapillary region (4 sectors, ROI: 2.67 mm2) were performed before (-) and 30 minutes after application of phenylephrine 5% and tropicamide 0.5% (+) eye drops (scan size was 8.41 mm2). Macula microcirculation was quantified in 3 retinal layers (superficial vascular plexus (SVP), deep capillary plexus (DCP), intermediate capillary plexus (ICP)). Data analysis was performed with the Erlangen-Angio-Tool. (I) Mean VD was 33.03±2.3 (SVP), 23.53±2.9 (ICP) and 25.48±4.2 (DCP) before and 33.12±2.4 (SVP), 23.74±2.9 (ICP) and 25.82±4.0 (DCP) with mydriasis respectively. (II) Sectorial analysis: 30.63±2.9–34.45±2.9 (-) and 31.04±2.9–34.34±2.7 (+) in SVP; 22.61±2.9–24.93±3.2 (-) and 22.75±2.5–25.20±3.0 (+) in ICP; 24.56±4.7–26.45±3.4 (-) and 25.00±4.1–27.07±3.5 (+) in DCP. (III) Peripapillary region showed a mean VD of 31.82±3.8 before and 31.59±4.3 after mydriasis. Sectorial analysis of VD yielded a range of 31.04±4.1–32.65±3.8 (-) and 30.98±4.4–31.89±4.1 (+). (IV) Macula and peripapillary VD were not different before and after mydriasis (p>0.05). Pharmacologic mydriasis did not influence retinal microcirculation in macula and peripapillary region enabling OCT-A scans with enhanced imaging process and scan quality. [ABSTRACT FROM AUTHOR]
- Abstract:
Copyright of PLoS ONE is the property of Public Library of Science and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
No Comments.