Item request has been placed!
×
Item request cannot be made.
×
Processing Request
Utility of temperature‐sensitive indicators for temperature monitoring of red‐blood‐cell units.
Item request has been placed!
×
Item request cannot be made.
×
Processing Request
- Author(s): Park, Mikyoung1 (AUTHOR); Hur, Mina1 (AUTHOR) ; Yi, Ahram2 (AUTHOR); Kim, Hanah1 (AUTHOR); Lee, Hyun Kyung1 (AUTHOR); Jeon, Eun Young3 (AUTHOR); Oh, Kyung‐Mi3 (AUTHOR); Lee, Mark Hong4 (AUTHOR)
- Source:
Vox Sanguinis. Jul2019, Vol. 114 Issue 5, p487-494. 8p. 1 Color Photograph, 2 Charts, 3 Graphs.
- Subject Terms:
- Additional Information
- Subject Terms:
- Abstract:
Background and Objectives: The 30‐min rule has been used to maintain a core temperature (CT) of red‐blood‐cell (RBC) units below 10°C during transportation. We evaluated the utility of temperature‐sensitive indicators (TIs) to monitor the surface temperature (ST) of RBC units and to explore whether TIs can help with compliance with the 30‐min rule by extrapolating or correlating temperature change with time. Materials and Methods: Two US FDA‐approved TIs, Safe‐T‐Vue 10 (STV10; Temptime Corporation, Morris Plains, NJ, USA) and Timestrip Blood Temp 10 (BT10; Timestrip UK Ltd, Cambridge, UK), were attached to 50 RBC units. After issue, their colour change indicating 10°C was monitored, and temperature excursions were measured by standard reading. In additional 18 RBC units, both ST and CT were monitored simultaneously. Results: In 50 RBC units, 94% of STV10 and 100% of BT10 showed colour change indicating 10°C within 30 min; 4% of STV10 and 18% of BT10 showed it during transportation. The time for colour change indicating 10°C differed significantly between STV10 and BT10 (19·0 vs. 5·6 min, P < 0·001). In additional 18 RBC units, 83·3% of STV10, 100% of BT10 and 88·9% of CT reached 10°C within 30 min, and the time for colour change indicating 10°C was 24·4 min in STV10, 14·6 min in BT 10 and 24·2 min in CT (P < 0·001). Conclusion: In two TIs, the time for colour change indicating 10°C varied considerably. To enhance the utility of TIs, further improvement and standardization would be needed. [ABSTRACT FROM AUTHOR]
- Abstract:
Copyright of Vox Sanguinis is the property of Wiley-Blackwell and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
No Comments.