[Blood pressure in neonates measured by Doppler ultrasound].
Item request has been placed!
×
Item request cannot be made.
×
Processing Request
- Additional Information
- Transliterated Title:
Krvni tlak novorodencadi mjeren Dopplerovom ultrazvucnom tehnikom.
- Source:
Publisher: Zbor Lijecnika Hrvatske Country of Publication: Croatia NLM ID: 0074253 Publication Model: Print Cited Medium: Print ISSN: 0024-3477 (Print) Linking ISSN: 00243477 NLM ISO Abbreviation: Lijec Vjesn Subsets: MEDLINE
- Publication Information:
Original Publication: Zagreb : Zbor Lijecnika Hrvatske
- Subject Terms:
- Abstract:
In order to provide correct care for newborns it is necessary to determine the arterial pressure, since it is an important physiological indicator of body vitality. We measured blood pressure in 50 healthy, full term infants, born in Zagreb. All blood pressure readings were done by using a Doppler ultrasound. The 4 cm width cuff was used. The mean systolic pressure was 78.76 mmHg (SD +/- 8.6) and the diastolic one 35.78 mmHg (SD +/- 6). The level of systolic pressure was associated with body-mass (r = 0.371; p < 0.01), while sex had no effect on it.