Item request has been placed!
×
Item request cannot be made.
×
Processing Request
Affordable CD4(+) T-cell counts on 'single-platform' flow cytometers I. Primary CD4 gating.
Item request has been placed!
×
Item request cannot be made.
×
Processing Request
- Author(s): Janossy G;Janossy G; Jani I; Göhde W
- Source:
British journal of haematology [Br J Haematol] 2000 Dec; Vol. 111 (4), pp. 1198-208.
- Publication Type:
Journal Article
- Language:
English
- Additional Information
- Source:
Publisher: Wiley-Blackwell Country of Publication: England NLM ID: 0372544 Publication Model: Print Cited Medium: Print ISSN: 0007-1048 (Print) Linking ISSN: 00071048 NLM ISO Abbreviation: Br J Haematol Subsets: MEDLINE
- Publication Information:
Publication: Oxford : Wiley-Blackwell
Original Publication: Oxford : Blackwell Scientific Publications
- Subject Terms:
- Abstract:
Here, we demonstrate the flow cytometric concept of 'primary CD4 gating' utilizing three different CD4 monoclonal antibodies (mAbs) conjugated with five different fluorochromes. CD4(+) lymphocytes were defined by an autogate in a single histogram of CD4 fluorescence intensity (FI) (y-axis) vs. side light scatter (x-axis). A wide range of absolute counts for > 600 individuals, including HIV(+) patients, were compared with those obtained by 'state-of-the-art' single-platform flow cytometers such as the volumetric Ortho CytoronAbsolute and the Becton Dickinson FACSCalibur using TruCount beads. The correlation between CD4 counts obtained with primary CD4 gating and the full test panel on the Ortho Cytoron was excellent (R(2) = 0.999). Bland-Altman statistics showed a mean difference of -2 cells/mm(3) [confidence interval (CI) 95% = -3 to -1; limits of agreement -27 to +23]. In addition to absolute CD4 counts, CD4% values and CD4/CD8 ratios are also frequently requested. To obtain these, lymphocytes need to be counted using scatter gates, and a second tube stained with a CD8 mAb to count CD8(++) lymphocytes can be incorporated. We conclude that primary CD4 gating on single-platform volumetric flow cytometers is one of the most economical and flexible technologies for routine cost-conscious service work, particularly during the follow-up of patients undergoing anti-HIV therapy and/or vaccination in the developing world.
- Accession Number:
0 (Antibodies, Monoclonal)
0 (CD3 Complex)
0 (Fluorescent Dyes)
- Publication Date:
Date Created: 20010213 Date Completed: 20010308 Latest Revision: 20190705
- Publication Date:
20250114
- Accession Number:
10.1046/j.1365-2141.2000.02433.x
- Accession Number:
11167762
No Comments.