Endovascular biopsy: Technical feasibility of novel endothelial cell harvesting devices assessed in a rabbit aneurysm model.
Item request has been placed!
×
Item request cannot be made.
×
Processing Request
- Author(s): Cooke, Daniel L.; Bauer, Diana; Zhengda Sun; Stillson, Carol; Nelson, Jeffrey; Barry, David; Hetts, Steven W.; Higashida, Randall T.; Dowd, Christopher F.; Halbach, Van V.; Hua Su; Saeed, Maythem M.
- Source:
Interventional Neuroradiology; 2015, Vol. 21 Issue 1, p120-128, 9p
- Subject Terms:
- Additional Information
- Abstract:
The lack of safe and reliable methods to sample vascular tissue in situ limits discovery of the underlying genetic and pathophysiological mechanisms of many vascular disorders, including aneurysms. We investigated the feasibility and comparable efficacy of in vivo vascular endothelial cell sampling using a spectrum of endovascular devices. Using the rabbit elastase carotid aneurysm model we evaluated the performance of existing aneurysmal coils, intracranial stents, and stent-like devices to collect vascular endothelial cells. Additionally, we modified a subset of devices to assess the effects of alterations to coil pitch, coil wire contour, and stent surface finishing. Device performance was evaluated by (1) the number of viable endothelial cells harvested, (2) the degree of vascular wall damage analyzed using digital subtraction angiography and histopathological analysis, and (3) the ease of device navigability and retrieval. Isolated cells underwent immunohistochemical analysis to confirm cell type and viability. Coil and stent specifications, technique, and endothelial cell counts were tabulated and statistical analysis performed. Using conventional detachable-type and modified aneurysm coils 11 of 14 (78.6%) harvested endothelial cells with a mean of 7.93 (±8.33) cells/coil, while 15 of 15 (100%) conventional stents, stent-like devices and modified stents harvested endothelial cells with a mean of 831.33 (±887.73) cells/device. Coil stiffness was significantly associated with endothelial cell count in univariate analysis (p=0.044). For stents and stent-like devices univariate analysis demonstrated stent-to-aorta diameter ratios (p=0.001), stent length (p=0.049), and the use of a pulling retrieval technique (p=0.019) significantly predictive of endothelial cell counts, though a multivariate model using these variables demonstrated only the stent-to-aorta diameter ratio (p=0.029) predictive of endothelial cell counts. Modified devices did not significantly impact harvesting. The efficacy and safety of existing aneurysm coils, intracranial stents and stent-like devices in collecting viable endothelial cells was confirmed. The technique is reproducible and the quantity and quality of collected endothelial cells is adequate for targeted genetic analysis. [ABSTRACT FROM AUTHOR]
- Abstract:
Copyright of Interventional Neuroradiology is the property of Sage Publications, Ltd. and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)